{"_buckets": {"deposit": "00614605-ce74-4087-b44d-bd71b7aba5e8"}, "_deposit": {"id": "18628", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "18628"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00018628", "sets": ["675"]}, "author_link": ["54159", "54160", "54161", "54162", "54163", "54164"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "032020", "bibliographicPageStart": "032020", "bibliographicVolumeNumber": "234", "bibliographic_titles": [{"bibliographic_title": "Journal of Physics: Conference Series", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper discusses electrical insulation characteristics of high temperature superconducting (HTS) cables for their reliable and rational insulation design. We focused on a severe and practical operational condition of HTS cables, i.e. under commercial ac / lightning impulse superimposed voltage. Experimental results for a HTS cable insulation model composed of liquid nitrogen (LN2) and polypropylene (PP) laminated paper revealed that ac / impulse superimposed voltage could trigger partial discharge (PD) by the impulse voltage invasion and cause consecutive PD under the subsequent ac voltage. The PD generation characteristics were summarized for different ac / impulse superimposed voltages, and a criterion for consecutive PD generation was identified.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Eucas \u002709: The 9th European Conference on Applied Superconductivity (Dresden, Germany, 13–17 September 2009)", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "http://dx.doi.org/10.1088/1742-6596/234/3/032020"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/20725"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IOP Publishing", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1088/1742-6596/234/3/032020", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Published under licence in Journal of Physics: Conference Series by IOP Publishing Ltd.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1742-6588", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayakawa, N", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "54159", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaguchi, R", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "54160", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ukai, Y", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "54161", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kojima, H", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "54162", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, F", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "54163", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okubo, H", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "54164", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "1742-6596_234_3_032020.pdf", "filesize": [{"value": "537.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 537600.0, "url": {"label": "1742-6596_234_3_032020.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/18628/files/1742-6596_234_3_032020.pdf"}, "version_id": "74c67c49-4dbd-4353-b6dd-1d6f4e12e4e4"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Partial Discharge Activities under AC/Impulse Superimposed Voltage in LN2/Polypropylene Laminated Paper Insulation System for HTS Cables", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Partial Discharge Activities under AC/Impulse Superimposed Voltage in LN2/Polypropylene Laminated Paper Insulation System for HTS Cables", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["675"], "permalink_uri": "http://hdl.handle.net/2237/20725", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2014-11-07"}, "publish_date": "2014-11-07", "publish_status": "0", "recid": "18628", "relation": {}, "relation_version_is_last": true, "title": ["Partial Discharge Activities under AC/Impulse Superimposed Voltage in LN2/Polypropylene Laminated Paper Insulation System for HTS Cables"], "weko_shared_id": -1}
Partial Discharge Activities under AC/Impulse Superimposed Voltage in LN2/Polypropylene Laminated Paper Insulation System for HTS Cables
http://hdl.handle.net/2237/20725
http://hdl.handle.net/2237/20725eb3cc89e-dd97-4411-8da5-e8c61b60ce6c
名前 / ファイル | ライセンス | アクション |
---|---|---|
1742-6596_234_3_032020.pdf (537.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-11-07 | |||||
タイトル | ||||||
タイトル | Partial Discharge Activities under AC/Impulse Superimposed Voltage in LN2/Polypropylene Laminated Paper Insulation System for HTS Cables | |||||
言語 | en | |||||
著者 |
Hayakawa, N
× Hayakawa, N× Yamaguchi, R× Ukai, Y× Kojima, H× Endo, F× Okubo, H |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | Published under licence in Journal of Physics: Conference Series by IOP Publishing Ltd. | |||||
抄録 | ||||||
内容記述 | This paper discusses electrical insulation characteristics of high temperature superconducting (HTS) cables for their reliable and rational insulation design. We focused on a severe and practical operational condition of HTS cables, i.e. under commercial ac / lightning impulse superimposed voltage. Experimental results for a HTS cable insulation model composed of liquid nitrogen (LN2) and polypropylene (PP) laminated paper revealed that ac / impulse superimposed voltage could trigger partial discharge (PD) by the impulse voltage invasion and cause consecutive PD under the subsequent ac voltage. The PD generation characteristics were summarized for different ac / impulse superimposed voltages, and a criterion for consecutive PD generation was identified. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
内容記述 | ||||||
内容記述 | Eucas '09: The 9th European Conference on Applied Superconductivity (Dresden, Germany, 13–17 September 2009) | |||||
言語 | en | |||||
内容記述タイプ | Other | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | IOP Publishing | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/1742-6596/234/3/032020 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1742-6588 | |||||
書誌情報 |
en : Journal of Physics: Conference Series 巻 234, 号 3, p. 032020-032020, 発行日 2010 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://dx.doi.org/10.1088/1742-6596/234/3/032020 | |||||
識別子タイプ | DOI | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/20725 | |||||
識別子タイプ | HDL |