{"created":"2021-03-01T06:17:02.210611+00:00","id":10223,"links":{},"metadata":{"_buckets":{"deposit":"36812867-a0cf-4ed3-bcda-08dd9e4112e8"},"_deposit":{"id":"10223","owners":[],"pid":{"revision_id":0,"type":"depid","value":"10223"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00010223","sets":["320:321:322"]},"author_link":["30955","30956","30957","30958","30959"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"140","bibliographicPageStart":"137","bibliographicVolumeNumber":"1034","bibliographic_titles":[{"bibliographic_title":"AIP Conference Proceedings","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The indoor radioactive aerosols of radon decay products are considered as a main radioactive contaminant in human environment. In this study, the particle size distribution was measured with low pressure cascade impactor and imaging plate. The temporal and spatial variations of indoor radioactive aerosols were measured at eight indoor sites of Nagoya, Japan. Effective doses were assessed using ICRP 66 and UNSCEAR 2000 approaches.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1063/1.2991191"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/12043"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"American Institite of Physics","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.2991191","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (2008) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0094-243X","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"lida, Takao","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Rahman, Naureen Mahbub","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30956","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsui, Akihiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30957","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamazawa, Hiromi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30958","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Moriizumi, Jun","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30959","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"34225013.pdf","filesize":[{"value":"513.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"34225013.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/10223/files/34225013.pdf"},"version_id":"834ebdff-79ef-48f5-87cc-dcf5bf67655a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"radioactive aerosol","subitem_subject_scheme":"Other"},{"subitem_subject":"radon decay products","subitem_subject_scheme":"Other"},{"subitem_subject":"particle size distribution","subitem_subject_scheme":"Other"},{"subitem_subject":"low pressure","subitem_subject_scheme":"Other"},{"subitem_subject":"cascade impactor","subitem_subject_scheme":"Other"},{"subitem_subject":"imaging plate","subitem_subject_scheme":"Other"},{"subitem_subject":"effective dose","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"The Measurement of Size Distribution of Indoor Natural Radioactive Aerosols by Imaging Plate Technique","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The Measurement of Size Distribution of Indoor Natural Radioactive Aerosols by Imaging Plate Technique","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-08-18"},"publish_date":"2009-08-18","publish_status":"0","recid":"10223","relation_version_is_last":true,"title":["The Measurement of Size Distribution of Indoor Natural Radioactive Aerosols by Imaging Plate Technique"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:56:05.839937+00:00"}