Particle Size Identification in GIS by Ultra High Speed Measurement of Partial Discharge

http://hdl.handle.net/2237/12055
http://hdl.handle.net/2237/12055
589eea1b-567d-4626-bae8-e01352e69993
名前 / ファイル ライセンス アクション
1_partial_size.pdf 1_partial_size.pdf (1.5 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-08-20
タイトル
タイトル Particle Size Identification in GIS by Ultra High Speed Measurement of Partial Discharge
言語 en
著者 Nishizawa, Kanako

× Nishizawa, Kanako

WEKO 31002

en Nishizawa, Kanako

Search repository
Okusu, Takashi

× Okusu, Takashi

WEKO 31003

en Okusu, Takashi

Search repository
Kojima, Hiroki

× Kojima, Hiroki

WEKO 31004

en Kojima, Hiroki

Search repository
Hayakawa, Naoki

× Hayakawa, Naoki

WEKO 31005

en Hayakawa, Naoki

Search repository
Endo, Fumihiro

× Endo, Fumihiro

WEKO 31006

en Endo, Fumihiro

Search repository
Yoshida, Masanobu

× Yoshida, Masanobu

WEKO 31007

en Yoshida, Masanobu

Search repository
Uchida, Katsumi

× Uchida, Katsumi

WEKO 31008

en Uchida, Katsumi

Search repository
Okubo, Hitoshi

× Okubo, Hitoshi

WEKO 31009

en Okubo, Hitoshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 Copyright © 2008 IEEE. Reprinted from International Conference on Condition Monitoring and Diagnosis, 2008. CMD 2008. p.443-447. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE<br/> endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.
抄録
内容記述タイプ Abstract
内容記述 Gas insulated switchgear (GIS) is reliable equipment. However, when a metallic particle is in it, the insulation reliability of GIS sometimes reduces. Partial discharge (PD) measurement is usually performed to detect a metallic particle in GIS. After the PD detection, the criticality of PD must be estimated. For this purpose, identification of a particle size is very important. In this paper, every PD pulse of various particle sizes was measured sequentially with an ultra-high speed measuring system. And physical PD parameters were systematically analyzed. As a result, it was clarified that identification of the particle size was possible by considering the PD pulse number and current at positive and negative polarities. Finally, correspondence between electromagnetic wave emitted from PD and PD current was discussed.
言語 en
出版者
出版者 IEEE
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/CMD.2008.4580321
書誌情報 en : International Conference on Condition Monitoring and Diagnosis (CMD 2008)

p. 443-447, 発行日 2008-04
フォーマット
値 application/pdf
著者版フラグ
値 author
URI
識別子 http://dx.doi.org/10.1109/CMD.2008.4580321
識別子タイプ DOI
URI
識別子 http://hdl.handle.net/2237/12055
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 19:33:33.227550
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3