{"created":"2021-03-01T06:17:03.217203+00:00","id":10239,"links":{},"metadata":{"_buckets":{"deposit":"e704e63a-51dd-412b-9f25-c48945574d67"},"_deposit":{"id":"10239","owners":[],"pid":{"revision_id":0,"type":"depid","value":"10239"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00010239","sets":["320:502:503"]},"author_link":["31026","31027","31028","31029","31030"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"4","bibliographicPageStart":"1","bibliographic_titles":[{"bibliographic_title":"IEEE International Conference on Dielectric Liquids (ICDL 2008)","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have been discussing the partial discharge (PD) inception characteristics of liquid nitrogen (LN_2) / polypropylene (PP) laminated paper composite insulation system for high temperature superconducting (HTS) cables. Based on the volume effect on PD inception electric field strength (PDIE) with a parameter called SSLV (statistical stressed liquid volume), in this paper, we evaluated PDIE of a full-scale HTS cable sample. Experimental results revealed that PDIE of the full-scale HTS cable sample at atmospheric LN_2 pressure under AC voltage application was consistent with the minimum PDIE value in the previous experiments. These results verify that 17.4 kV_rms/mm obtained in this paper can be regarded as a criterion of PDIE in consideration of the volume effect for the practical insulation design of actual HTS cables.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/ICDL.2008.4622518"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/12059"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/ICDL.2008.4622518","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2008 IEEE. Reprinted from IEEE International Conference on Dielectric Liquids, 2008. ICDL 2008. p.1-4. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, Naoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31026","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaguchi, Ryutaro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31027","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kojima, Hiroki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31028","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, Fumihiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31029","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, Hitoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31030","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"ICDL_Partial_Discharge_Inception.pdf","filesize":[{"value":"996.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ICDL_Partial_Discharge_Inception.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/10239/files/ICDL_Partial_Discharge_Inception.pdf"},"version_id":"fc28fe47-40c4-4621-9dac-a4472638d6ad"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Partial Discharge Inception Strength in a Full-scale HTS Cable Based on LN2/Polypropylene Laminated Paper Insulation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Partial Discharge Inception Strength in a Full-scale HTS Cable Based on LN2/Polypropylene Laminated Paper Insulation","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["503"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-08-21"},"publish_date":"2009-08-21","publish_status":"0","recid":"10239","relation_version_is_last":true,"title":["Partial Discharge Inception Strength in a Full-scale HTS Cable Based on LN2/Polypropylene Laminated Paper Insulation"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:56:12.800897+00:00"}