{"created":"2021-03-01T06:17:03.278896+00:00","id":10240,"links":{},"metadata":{"_buckets":{"deposit":"308c799c-85ca-4be9-817a-49263fe1bc33"},"_deposit":{"id":"10240","owners":[],"pid":{"revision_id":0,"type":"depid","value":"10240"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00010240","sets":["320:502:503"]},"author_link":["31031","31032","31033","31034","31035","31036","31037","31038"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-04","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"50","bibliographicPageStart":"46","bibliographic_titles":[{"bibliographic_title":"International Conference on Condition Monitoring and Diagnosis (CMD 2008)","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A metallic particle appeared in a gas insulated switchgear (GIS) sometimes adheres on a solid spacer surface. If the adhered metallic particle is exposed to a surge high voltage, a breakdown (BD) may be induced. Therefore, it is eagerly demanded to diagnose its risk correctly under the service voltage by partial discharge (PD) measurement. In this paper, particle-initiated surface PD characteristics were systematically studied in 0.4 MPa SF_6 gas by changing the sizes of particles. PD inception voltage (PDIV), temporal change of PD current and the PD pulse number were analyzed in detail. Furthermore, comparing with PD characteristics of particles in a gas gap, the influence of the solid insulator on the PD characteristics was clarified. It was found out that PD characteristics greatly changed with time owing to electric charges deposited on a spacer surface.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/CMD.2008.4580227"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/12060"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/CMD.2008.4580227","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2008 IEEE. Reprinted from International Conference on Condition Monitoring and Diagnosis, 2008. CMD 2008. p.46-50. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted.
However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, Naoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31031","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okusu, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31032","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishizawa, Kanako","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31033","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kojima, Hiroki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31034","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, Fumihiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31035","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshida, Masanobu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31036","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Katsumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31037","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, Hitoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31038","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"CMD_Dependence_of_Partial_Discharge.pdf","filesize":[{"value":"573.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"CMD_Dependence_of_Partial_Discharge.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/10240/files/CMD_Dependence_of_Partial_Discharge.pdf"},"version_id":"b9dcf68f-87ca-42bc-9780-8c66fdff52c2"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Dependence of Partial Discharge Characteristics at Spacer Surface on Particle Size in SF_6 Gas Insulated System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Dependence of Partial Discharge Characteristics at Spacer Surface on Particle Size in SF_6 Gas Insulated System","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["503"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-08-21"},"publish_date":"2009-08-21","publish_status":"0","recid":"10240","relation_version_is_last":true,"title":["Dependence of Partial Discharge Characteristics at Spacer Surface on Particle Size in SF_6 Gas Insulated System"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:58:07.679564+00:00"}