{"created":"2021-03-01T06:17:03.341357+00:00","id":10241,"links":{},"metadata":{"_buckets":{"deposit":"aae9acdc-3ed0-4fec-ad6b-b5617f7bdeb4"},"_deposit":{"id":"10241","owners":[],"pid":{"revision_id":0,"type":"depid","value":"10241"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00010241","sets":["673:674:675"]},"author_link":["31039","31040","31041","31042","31043","31044"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"654","bibliographicPageStart":"647","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Dielectrics and Electrical Insulation","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper discusses electrical insulation characteristics of liquid nitrogen (LN_2) / polypropylene (PP) laminated paper composite insulation system for the practical electrical insulation design of high temperature superconducting (HTS) cables. Partial discharge (PD) inception, propagation and breakdown (BD) characteristics under ac voltage application were obtained and discussed at atmospheric and pressurized conditions. Experimental results were analyzed quantitatively and revealed that void-type discharge was categorized as an important form of discharge to characterize the transition of PD activity leading to BD.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/TDEI.2008.4543100"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/12061"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TDEI.2008.4543100","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2008 IEEE. Reprinted from IEEE Transactions on Dielectrics and Electrical Insulation, v.15, n.3, 2008, p.647-654.
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted.
However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1070-9878","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Okubo, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31039","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kojima, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31040","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, F.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31041","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sahara, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31042","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaguchi, R.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31043","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, N.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31044","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"Partial_Discharge_Activity_in_Electrical_Insulation.pdf","filesize":[{"value":"3.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Partial_Discharge_Activity_in_Electrical_Insulation.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/10241/files/Partial_Discharge_Activity_in_Electrical_Insulation.pdf"},"version_id":"c50e0088-d137-44d3-b9ce-313b005b8e71"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Superconducting cables","subitem_subject_scheme":"Other"},{"subitem_subject":"dielectric liquids","subitem_subject_scheme":"Other"},{"subitem_subject":"paper insulation","subitem_subject_scheme":"Other"},{"subitem_subject":"partial discharges","subitem_subject_scheme":"Other"},{"subitem_subject":"electrical breakdown","subitem_subject_scheme":"Other"},{"subitem_subject":"laminated paper","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Partial Discharge Activity in Electrical Insulation for High Temperature Superconducting (HTS) Cables","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Partial Discharge Activity in Electrical Insulation for High Temperature Superconducting (HTS) Cables","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-08-21"},"publish_date":"2009-08-21","publish_status":"0","recid":"10241","relation_version_is_last":true,"title":["Partial Discharge Activity in Electrical Insulation for High Temperature Superconducting (HTS) Cables"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:48:19.808776+00:00"}