{"created":"2021-03-01T06:18:34.319672+00:00","id":11666,"links":{},"metadata":{"_buckets":{"deposit":"eebea430-960b-48a1-a7c6-64f542b925e7"},"_deposit":{"created_by":17,"id":"11666","owners":[17],"pid":{"revision_id":0,"type":"depid","value":"11666"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00011666","sets":["879:1183:1184:1238"]},"author_link":["81242","81243","81244","81245","81246","81247","81248","81249","81250","81251","81252","81253","81254","81255"],"item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Preliminary results of 2000-fourth international radiocarbon intercomparison : international blind test of <14>^C measurement","subitem_alternative_title_language":"en"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"40","bibliographicPageStart":"29","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"名古屋大学加速器質量分析計業績報告書","bibliographic_titleLang":"ja"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A Tandetron accelerator mass spectrometer (Tandetron-I AMS system), an apparatus dedicated to high sensitivity radiocarbon (^<14>C) measurements, manufactured by General Ionex Corporation, USA, has been used since 1983 to measure the ^<14>C concentrations of environmental samples as well as ^<14>C dates of geological and archaeological materials, at the Center for Chronological Research (CCR), Nagoya University. In the meanwhile, a so-called second generation AMS ^<14>C apparatus (Tandetron-II AMS system) manufactured by High Voltage Engineering Europe, BV, the Netherlands has been installed successfully at CCR in 1997. Though we had experienced a lot of difficulties with the Tandetron-II just two years after its installation, we were able to start ^<14>C measurements with the machine in acceptable precision since the end of 1999. The ^<14>C measurement error (one sigma error)of the Tandetron-II is around ±20 - ±40 years, which is clearly smaller than that of the Tandetron-I (around ±50 - ±90 years). In addition, the reproducibility tests of ^<14>C measurements for the IAEA C1- C8 ^<14>C standards suggest that accuracy of ^<14>C measurement can be as good as around 0.5% We participated the Forth International Radiocarbon Intercomparison (FIRI) program started in 1999,after its set up at the time of the 15^