{"_buckets": {"deposit": "bc51b6eb-16a2-41af-ad23-eca25acaaba1"}, "_deposit": {"id": "12009", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "12009"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00012009", "sets": ["322"]}, "author_link": ["38058", "38059", "38060", "38061", "38062", "38063"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-09-24", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1359", "bibliographicPageStart": "1356", "bibliographic_titles": [{"bibliographic_title": "Nuclear Science Symposium Conference Record (NSS/MIC)", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A neutron spectrometer with associated particles coincident time-of-flight technique is being developed for deuterium plasma experiments in a large helical fusion device. In this experiment, the energy resolution less than 7% and the detection efficiency larger than 10-6 counts/neutron is required for the plasma diagnostics based on neutron spectrometry. The prototype spectrometer was partly assembled and the detector performance was experimentally checked at Fusion Neutron Source of Japan Atomic Energy Agency. By selecting the events with low energy loss from all coincident events in the radiator, the experimental results showed that the neutron spectrometer could achieve an energy resolution around 6.7% under a detection efficiency of 3.3Ã 10-7 counts/neutron for DD neutrons. To improve the detection efficiency, the configuration of the neutron spectrometer system was designed toward the DD plasma experiment at an existent large helical fusion device.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/13885"}, {"subitem_identifier_type": "DOI", "subitem_identifier_uri": "http://dx.doi.org/10.1109/NSSMIC.2009.5402336"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/NSSMIC.2009.5402336", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "©2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1082-3654", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Iwai, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "38058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iguchi, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "38059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tomita, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "38060", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawarabayashi, J.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "38061", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Isobe, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "38062", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Konno, C.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "38063", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "iguchi.pdf", "filesize": [{"value": "230.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 230000.0, "url": {"label": "iguchi.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/12009/files/iguchi.pdf"}, "version_id": "50648c03-8c85-460e-ada4-f5a4c0e80d88"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of 2.5MeV neutron spectrometer for helical deuterium plasma experiment", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of 2.5MeV neutron spectrometer for helical deuterium plasma experiment", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/13885", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-07-30"}, "publish_date": "2010-07-30", "publish_status": "0", "recid": "12009", "relation": {}, "relation_version_is_last": true, "title": ["Development of 2.5MeV neutron spectrometer for helical deuterium plasma experiment"], "weko_shared_id": -1}
Development of 2.5MeV neutron spectrometer for helical deuterium plasma experiment
http://hdl.handle.net/2237/13885
http://hdl.handle.net/2237/13885d623dda8-e462-4ec4-8dab-7fb3861511c6
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-07-30 | |||||
タイトル | ||||||
タイトル | Development of 2.5MeV neutron spectrometer for helical deuterium plasma experiment | |||||
言語 | en | |||||
著者 |
Iwai, H.
× Iwai, H.× Iguchi, T.× Tomita, H.× Kawarabayashi, J.× Isobe, M.× Konno, C. |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | ©2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. | |||||
抄録 | ||||||
内容記述 | A neutron spectrometer with associated particles coincident time-of-flight technique is being developed for deuterium plasma experiments in a large helical fusion device. In this experiment, the energy resolution less than 7% and the detection efficiency larger than 10-6 counts/neutron is required for the plasma diagnostics based on neutron spectrometry. The prototype spectrometer was partly assembled and the detector performance was experimentally checked at Fusion Neutron Source of Japan Atomic Energy Agency. By selecting the events with low energy loss from all coincident events in the radiator, the experimental results showed that the neutron spectrometer could achieve an energy resolution around 6.7% under a detection efficiency of 3.3Ã 10-7 counts/neutron for DD neutrons. To improve the detection efficiency, the configuration of the neutron spectrometer system was designed toward the DD plasma experiment at an existent large helical fusion device. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | IEEE | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/NSSMIC.2009.5402336 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1082-3654 | |||||
書誌情報 |
en : Nuclear Science Symposium Conference Record (NSS/MIC) p. 1356-1359, 発行日 2009-09-24 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/13885 | |||||
識別子タイプ | HDL | |||||
URI | ||||||
識別子 | http://dx.doi.org/10.1109/NSSMIC.2009.5402336 | |||||
識別子タイプ | DOI |