{"created":"2021-03-01T06:18:59.702136+00:00","id":12061,"links":{},"metadata":{"_buckets":{"deposit":"1d2e1dfd-6d9a-4e17-9f61-e3bc99900909"},"_deposit":{"id":"12061","owners":[],"pid":{"revision_id":0,"type":"depid","value":"12061"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00012061"},"item_10_biblio_info_6":{"attribute_name":"\u66f8\u8a8c\u60c5\u5831","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"1883","bibliographicPageStart":"1880","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity"}]}]},"item_10_description_4":{"attribute_name":"\u6284\u9332","attribute_value_mlt":[{"subitem_description":"We have been developing superconducting fault current limiting transformer (SFCLT) as a superconducting transformer with current limiting function. As the step-5 of the SFCLT project for the up-graded ratings of current and voltage, in this paper, we focused on the up-grading of current by parallel-connected YBCO coated conductors. Based on the asymmetric configuration of coated conductors, different parallel connections were tested and evaluated in terms of critical current level and current limiting characteristics under large AC current at 77 K in liquid nitrogen.","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/13939"},{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/TASC.2009.2018067"}]},"item_10_publisher_32":{"attribute_name":"\u51fa\u7248\u8005","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_10_rights_12":{"attribute_name":"\u6a29\u5229","attribute_value_mlt":[{"subitem_rights":"\u00a92009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_10_select_15":{"attribute_name":"\u8457\u8005\u7248\u30d5\u30e9\u30b0","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"ISSN"}]},"item_10_text_14":{"attribute_name":"\u30d5\u30a9\u30fc\u30de\u30c3\u30c8","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_creator":{"attribute_name":"\u8457\u8005","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Omura, Koki"}],"nameIdentifiers":[{"nameIdentifier":"38258","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kojima, Hiroki"}],"nameIdentifiers":[{"nameIdentifier":"38259","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, Naoki"}],"nameIdentifiers":[{"nameIdentifier":"38260","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, Fumihiro"}],"nameIdentifiers":[{"nameIdentifier":"38261","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noe, Mathias"}],"nameIdentifiers":[{"nameIdentifier":"38262","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, Hitoshi"}],"nameIdentifiers":[{"nameIdentifier":"38263","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"\u30d5\u30a1\u30a4\u30eb\u60c5\u5831","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"Current_Limiting.pdf","filesize":[{"value":"750.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Current_Limiting.pdf","url":"https://nagoya.repo.nii.ac.jp/record/12061/files/Current_Limiting.pdf"},"version_id":"6e8accfd-1280-445b-88d2-966ec57724c9"}]},"item_keyword":{"attribute_name":"\u30ad\u30fc\u30ef\u30fc\u30c9","attribute_value_mlt":[{"subitem_subject":"Superconducting fault current limiter","subitem_subject_scheme":"Other"},{"subitem_subject":"YBCO coated conductor","subitem_subject_scheme":"Other"},{"subitem_subject":"superconducting transformer","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"\u8a00\u8a9e","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"\u8cc7\u6e90\u30bf\u30a4\u30d7","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Current Limiting Characteristics of Parallel-Connected Coated Conductors for High-Tc Superconducting Fault Current Limiting Transformer (HTc-SFCLT)","item_titles":{"attribute_name":"\u30bf\u30a4\u30c8\u30eb","attribute_value_mlt":[{"subitem_title":"Current Limiting Characteristics of Parallel-Connected Coated Conductors for High-Tc Superconducting Fault Current Limiting Transformer (HTc-SFCLT)"}]},"item_type_id":"10","owner":"1","path":["320/321/322"],"pubdate":{"attribute_name":"\u516c\u958b\u65e5","attribute_value":"2010-08-03"},"publish_date":"2010-08-03","publish_status":"0","recid":"12061","relation_version_is_last":true,"title":["Current Limiting Characteristics of Parallel-Connected Coated Conductors for High-Tc Superconducting Fault Current Limiting Transformer (HTc-SFCLT)"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2021-03-01T19:02:55.721740+00:00"}