@article{oai:nagoya.repo.nii.ac.jp:00001365, author = {IWASE, Satoshi and FU, Qi and NARITA, Kenichi and MORIMOTO, Eiichi and TAKADA, Hiroki and MANO, Tadaaki}, issue = {1/2}, journal = {Environmental medicine : annual report of the Research Institute of Environmental Medicine, Nagoya University}, month = {Dec}, note = {An artificial gravity and ergometric exercise loading device for human use was manufactured. It has the capacity of a max 2 G-load at the heart level, and a max 150W of work-load. Eight subjects (six completed) were subjected to four repeated trials with or without 20W ergometric exercise. Anti-G score, defined as the G-load × running time to the endpoint, was significantly higher in the exercise trials than standing trials. Heart rate (HR), mean arterial pressure (MAP), thoracic fluid index (TFI) were significantly superior during the exercise trials. Artificial gravity by centrifuge at 1.2 or 1.4 G with 40 or 60 W of ergometric workload may be an excellent countermeasure against cardiovascular deconditioning after long exposure to microgravity., 国立情報学研究所で電子化したコンテンツを使用している。}, pages = {29--32}, title = {Effects of Graded Load of Artificial Gravity on Cardiovascular Functions in Humans}, volume = {46}, year = {2002} }