{"_buckets": {"deposit": "692a07f7-7049-48e0-9310-1836b298880e"}, "_deposit": {"id": "14594", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "14594"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00014594", "sets": ["1395"]}, "author_link": ["83150", "83151"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Dawning of 14C-AMS studies at Nagoya University (1980-1990)", "subitem_alternative_title_language": "en"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "36", "bibliographicPageStart": "23", "bibliographicVolumeNumber": "22", "bibliographic_titles": [{"bibliographic_title": "名古屋大学加速器質量分析計業績報告書", "bibliographic_titleLang": "ja"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A plan to establish an AMS facility dedicated to radiocarbon (14C) measurement, discussed by Prof. Nakai and his colleagues, was authorized in 1978 at Nagoya University. Dr. Ken Purser, the president of General Ionex Corporation, USA, was invited to Nagoya University to present a talk on his plan to manufacture an ultra-sensitive mass spectrometer for natural-level 14C measurement. In the end, his second product, a model 4130-AMS 14C analyzer, was successfully introduced into the Radioisotope Center, Nagoya University, in 1981/82. The first 14C signal was detected with the machine in February 1983 and routine 14C measurements were started in the autumn of 1983. The AMS system has processed totally 8,612 unknown samples by July in 2000, after that time, he transferred his role of 14C measurements to another new successor. A second AMS system, dedicated to high-precision and high-accuracy 14C measurement, with a recombinator system to measure three carbon isotopes 12C, 13C and 14C simultaneously, produced by High Voltage Engineering Europe BV, The Netherlands was installed in 1996/97. The machine has been in operation since 2O00. The initial stage of 14C-AMS research at Nagoya University is summarized in this article.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "第23回名古屋大学年代測定総合研究センターシンポジウム平成22(2010)年度報告", "subitem_description_language": "ja", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/sumrua.22.23", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "名古屋大学年代測定資料研究センター", "subitem_publisher_language": "ja"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "中村, 俊夫", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "83150", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAKAMURA, Toshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "83151", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "sumrua_22_23.pdf", "filesize": [{"value": "4.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 4000000.0, "url": {"label": "sumrua_22_23.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/14594/files/sumrua_22_23.pdf"}, "version_id": "02414a7c-ba11-424e-aecf-f4bb98fa1a84"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "AMS", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ultra-sensitive mass spectrometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Radiocarbon", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Radiocarbon dating", "subitem_subject_scheme": "Other"}, {"subitem_subject": "cosmogenic nuclide", "subitem_subject_scheme": "Other"}, {"subitem_subject": "加速器質量分析", "subitem_subject_scheme": "Other"}, {"subitem_subject": "超高感度質量分析", "subitem_subject_scheme": "Other"}, {"subitem_subject": "放射性炭素", "subitem_subject_scheme": "Other"}, {"subitem_subject": "放射性炭素年代測定", "subitem_subject_scheme": "Other"}, {"subitem_subject": "宇宙線生成核種", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "名古屋大学における14C-AMS 研究の黎明期(1980-1990)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "名古屋大学における14C-AMS 研究の黎明期(1980-1990)", "subitem_title_language": "ja"}]}, "item_type_id": "9", "owner": "1", "path": ["1395"], "permalink_uri": "https://doi.org/10.18999/sumrua.22.23", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-06-04"}, "publish_date": "2012-06-04", "publish_status": "0", "recid": "14594", "relation": {}, "relation_version_is_last": true, "title": ["名古屋大学における14C-AMS 研究の黎明期(1980-1990)"], "weko_shared_id": -1}
名古屋大学における14C-AMS 研究の黎明期(1980-1990)
https://doi.org/10.18999/sumrua.22.23
https://doi.org/10.18999/sumrua.22.23c1ce83b6-8b0b-4e72-9739-dc1f0b07a31e
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-06-04 | |||||
タイトル | ||||||
タイトル | 名古屋大学における14C-AMS 研究の黎明期(1980-1990) | |||||
言語 | ja | |||||
その他のタイトル | ||||||
その他のタイトル | Dawning of 14C-AMS studies at Nagoya University (1980-1990) | |||||
言語 | en | |||||
著者 |
中村, 俊夫
× 中村, 俊夫× NAKAMURA, Toshio |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | AMS | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Ultra-sensitive mass spectrometer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Radiocarbon | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Radiocarbon dating | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cosmogenic nuclide | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 加速器質量分析 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 超高感度質量分析 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 放射性炭素 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 放射性炭素年代測定 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 宇宙線生成核種 | |||||
抄録 | ||||||
内容記述 | A plan to establish an AMS facility dedicated to radiocarbon (14C) measurement, discussed by Prof. Nakai and his colleagues, was authorized in 1978 at Nagoya University. Dr. Ken Purser, the president of General Ionex Corporation, USA, was invited to Nagoya University to present a talk on his plan to manufacture an ultra-sensitive mass spectrometer for natural-level 14C measurement. In the end, his second product, a model 4130-AMS 14C analyzer, was successfully introduced into the Radioisotope Center, Nagoya University, in 1981/82. The first 14C signal was detected with the machine in February 1983 and routine 14C measurements were started in the autumn of 1983. The AMS system has processed totally 8,612 unknown samples by July in 2000, after that time, he transferred his role of 14C measurements to another new successor. A second AMS system, dedicated to high-precision and high-accuracy 14C measurement, with a recombinator system to measure three carbon isotopes 12C, 13C and 14C simultaneously, produced by High Voltage Engineering Europe BV, The Netherlands was installed in 1996/97. The machine has been in operation since 2O00. The initial stage of 14C-AMS research at Nagoya University is summarized in this article. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
内容記述 | ||||||
内容記述 | 第23回名古屋大学年代測定総合研究センターシンポジウム平成22(2010)年度報告 | |||||
言語 | ja | |||||
内容記述タイプ | Other | |||||
出版者 | ||||||
言語 | ja | |||||
出版者 | 名古屋大学年代測定資料研究センター | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/sumrua.22.23 | |||||
ID登録タイプ | JaLC | |||||
書誌情報 |
ja : 名古屋大学加速器質量分析計業績報告書 巻 22, p. 23-36, 発行日 2011-03 |
|||||
著者版フラグ | ||||||
値 | publisher |