{"created":"2021-03-01T06:21:44.184715+00:00","id":14612,"links":{},"metadata":{"_buckets":{"deposit":"8ea9b8da-8a38-4c09-9dc5-5e9ac3e29b82"},"_deposit":{"id":"14612","owners":[],"pid":{"revision_id":0,"type":"depid","value":"14612"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00014612","sets":["879:1183:1184:1395"]},"author_link":["83292","83293","83294","83295","83296","83297","83298","83299"],"item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Current status of 14C measurement at JAEA-AMS-MUTSU","subitem_alternative_title_language":"en"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"173","bibliographicPageStart":"169","bibliographicVolumeNumber":"22","bibliographic_titles":[{"bibliographic_title":"名古屋大学加速器質量分析計業績報告書","bibliographic_titleLang":"ja"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An accelerator mass spectrometry at Aomori Research and Development Center, JAEA (JAEA-AMS-MUTSU) was established in 1997 and the routine operation of 14C and 129I measurement was started from 1999 and 2003, respectively. This AMS has adopted the open door policy for the general users from the fiscal year of 2006 and various researches have been in progress by many users. The total number of measurements has increased well for five years after the open door policy excluding in 2008. The reasons for the decrease in 2008 were that we had stopped the operation of AMS for about one and half months because the operation system of AMS was upgraded, and that we could not measure the 14C for several months because the amplifier of detector had broken. We had resolved this trouble and our AMS can measure smoothly.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"14C. 日本原子力研究開発機構青森研究開発センターにある加速器質量分析装置(JAEA-AMS-MUTSU)は、1997年に設置され、14C測定については1999年、129I測定については2003年から定常運転を開始した。2006年度からは外部利用者が利用可能な供用施設となり、多くの利用者により様々な研究活動に利用されるようになっている。本講演では、JAEA-AMS-MUTSU の現状を報告する。施設供用制度開始から5年間は、2009年度を除き、順調に測定数を増加させた。しかし、2009年度の測定数の減少は、制御システムの更新により、約1.5カ月間、加速器を停止させたこと、検出器のアンプの故障により、数か月間、14C測定が不可能であったことによるものである。現在は、問題も解消し、14C測定は順調に測定している。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_9_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"第23回名古屋大学年代測定総合研究センターシンポジウム平成22(2010)年度報告","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18999/sumrua.22.169","subitem_identifier_reg_type":"JaLC"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"名古屋大学年代測定資料研究センター","subitem_publisher_language":"ja"}]},"item_9_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 孝幸","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"83292","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"甲, 昭二","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"83293","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"木下, 尚喜","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"83294","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関, 武雄","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"83295","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, T","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"83296","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kabuto, S","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"83297","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kinoshita, N","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"83298","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Seki, T","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"83299","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"sumrua_22_169.pdf","filesize":[{"value":"542.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"sumrua_22_169.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/14612/files/sumrua_22_169.pdf"},"version_id":"981174c2-47c6-4534-bcc7-6f0b3d480641"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"加速器質量分析","subitem_subject_scheme":"Other"},{"subitem_subject":"14C","subitem_subject_scheme":"Other"},{"subitem_subject":"施設供用制度","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"JAEA-AMS-MUTSUにおける14C測定の現状","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"JAEA-AMS-MUTSUにおける14C測定の現状","subitem_title_language":"ja"}]},"item_type_id":"9","owner":"1","path":["1395"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-06-06"},"publish_date":"2012-06-06","publish_status":"0","recid":"14612","relation_version_is_last":true,"title":["JAEA-AMS-MUTSUにおける14C測定の現状"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:02:01.397371+00:00"}