{"_buckets": {"deposit": "1f743386-6ddf-4e8d-9bf9-1364c4da9321"}, "_deposit": {"created_by": 17, "id": "15445", "owners": [17], "pid": {"revision_id": 0, "type": "depid", "value": "15445"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00015445", "sets": []}, "author_link": ["98730"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1984-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-4", "bibliographicPageEnd": "66", "bibliographicPageStart": "55", "bibliographicVolumeNumber": "46", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Analysis of human motion is extremely important in order to obtain fundamental data for training in the field of rehabilitation. At Nagoya University we are analysing human motion by use of a microcomputer to elucidate functional characteristics of the locomotion system. After the introduction of micro-computers, it has become possible to accumulate and integrate more data and process them more quickly and conveniently. Data obtained from the weight balance analyzer, large force plate and three-dimensional goniometer devised by the authors are subjected to on-line processing through an A/D convertor. 1. The weight-balance analyzer for the evaluation of dynamic balance ability can be used both in standing and sitting positions. A computer block-break game is integrated into the program so that training can be performed enjoyably. 2. A large serial force plate is used to detect the floor reaction force of individual legs. Three force components in the directions of X, Y and Z are transformed to resultant force, velocity, acceleration and paths of center of pressure through mathematic processing. 3. The three-dimensinal goniometer describes angular changes of the hip or knee joint in the three planes during walking. In addition to flexion-cxtension, adduction-abduction and internal-external rotation can be grasped easily by this device.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.46.1-4.55", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4614/4614.html", "subitem_relation_type_select": "URI"}}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "EISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ITO, FUJIO", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "98730", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v46n14p55_66.pdf", "filesize": [{"value": "774.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 774500.0, "url": {"label": "v46n14p55_66.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/15445/files/v46n14p55_66.pdf"}, "version_id": "b41a5d49-5520-4218-9450-8f0401d17b51"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Micro-computer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Weight balance analyzer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Floor reaction force", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Three-dimensional goniometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Rehabilitation medicine", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Analysis of Human Motion in Rehabilitation by Micro-Computer", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Analysis of Human Motion in Rehabilitation by Micro-Computer", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "17", "path": ["1456"], "permalink_uri": "https://doi.org/10.18999/nagjms.46.1-4.55", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2013-02-08"}, "publish_date": "2013-02-08", "publish_status": "0", "recid": "15445", "relation": {}, "relation_version_is_last": true, "title": ["Analysis of Human Motion in Rehabilitation by Micro-Computer"], "weko_shared_id": -1}
Analysis of Human Motion in Rehabilitation by Micro-Computer
https://doi.org/10.18999/nagjms.46.1-4.55
https://doi.org/10.18999/nagjms.46.1-4.5529fd8aad-cb69-4471-8a0b-dc5abb676a16
名前 / ファイル | ライセンス | アクション |
---|---|---|
v46n14p55_66.pdf (774.5 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-02-08 | |||||
タイトル | ||||||
タイトル | Analysis of Human Motion in Rehabilitation by Micro-Computer | |||||
言語 | en | |||||
著者 |
ITO, FUJIO
× ITO, FUJIO |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Micro-computer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Weight balance analyzer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Floor reaction force | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Three-dimensional goniometer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Rehabilitation medicine | |||||
抄録 | ||||||
内容記述 | Analysis of human motion is extremely important in order to obtain fundamental data for training in the field of rehabilitation. At Nagoya University we are analysing human motion by use of a microcomputer to elucidate functional characteristics of the locomotion system. After the introduction of micro-computers, it has become possible to accumulate and integrate more data and process them more quickly and conveniently. Data obtained from the weight balance analyzer, large force plate and three-dimensional goniometer devised by the authors are subjected to on-line processing through an A/D convertor. 1. The weight-balance analyzer for the evaluation of dynamic balance ability can be used both in standing and sitting positions. A computer block-break game is integrated into the program so that training can be performed enjoyably. 2. A large serial force plate is used to detect the floor reaction force of individual legs. Three force components in the directions of X, Y and Z are transformed to resultant force, velocity, acceleration and paths of center of pressure through mathematic processing. 3. The three-dimensinal goniometer describes angular changes of the hip or knee joint in the three planes during walking. In addition to flexion-cxtension, adduction-abduction and internal-external rotation can be grasped easily by this device. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | Nagoya University School of Medicine | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.46.1-4.55 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4614/4614.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 46, 号 1-4, p. 55-66, 発行日 1984-03 |
|||||
著者版フラグ | ||||||
値 | publisher |