ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "1f743386-6ddf-4e8d-9bf9-1364c4da9321"}, "_deposit": {"id": "15445", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "15445"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00015445", "sets": ["1456"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1984-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-4", "bibliographicPageEnd": "66", "bibliographicPageStart": "55", "bibliographicVolumeNumber": "46", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Analysis of human motion is extremely important in order to obtain fundamental data for training in the field of rehabilitation. At Nagoya University we are analysing human motion by use of a microcomputer to elucidate functional characteristics of the locomotion system. After the introduction of micro-computers, it has become possible to accumulate and integrate more data and process them more quickly and conveniently. Data obtained from the weight balance analyzer, large force plate and three-dimensional goniometer devised by the authors are subjected to on-line processing through an A/D convertor. 1. The weight-balance analyzer for the evaluation of dynamic balance ability can be used both in standing and sitting positions. A computer block-break game is integrated into the program so that training can be performed enjoyably. 2. A large serial force plate is used to detect the floor reaction force of individual legs. Three force components in the directions of X, Y and Z are transformed to resultant force, velocity, acceleration and paths of center of pressure through mathematic processing. 3. The three-dimensinal goniometer describes angular changes of the hip or knee joint in the three planes during walking. In addition to flexion-cxtension, adduction-abduction and internal-external rotation can be grasped easily by this device.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.46.1-4.55", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_relation_43": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4614/4614.html", "subitem_relation_type_select": "URI"}}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ITO, FUJIO"}], "nameIdentifiers": [{"nameIdentifier": "98730", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v46n14p55_66.pdf", "filesize": [{"value": "774.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 774500.0, "url": {"label": "v46n14p55_66.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/15445/files/v46n14p55_66.pdf"}, "version_id": "b41a5d49-5520-4218-9450-8f0401d17b51"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Micro-computer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Weight balance analyzer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Floor reaction force", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Three-dimensional goniometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Rehabilitation medicine", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Analysis of Human Motion in Rehabilitation by Micro-Computer", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Analysis of Human Motion in Rehabilitation by Micro-Computer"}]}, "item_type_id": "9", "owner": "1", "path": ["1456"], "permalink_uri": "https://doi.org/10.18999/nagjms.46.1-4.55", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-02-08"}, "publish_date": "2013-02-08", "publish_status": "0", "recid": "15445", "relation": {}, "relation_version_is_last": true, "title": ["Analysis of Human Motion in Rehabilitation by Micro-Computer"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 46(1-4)

Analysis of Human Motion in Rehabilitation by Micro-Computer

https://doi.org/10.18999/nagjms.46.1-4.55
https://doi.org/10.18999/nagjms.46.1-4.55
29fd8aad-cb69-4471-8a0b-dc5abb676a16
名前 / ファイル ライセンス アクション
v46n14p55_66.pdf v46n14p55_66.pdf (774.5 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2013-02-08
タイトル
タイトル Analysis of Human Motion in Rehabilitation by Micro-Computer
著者 ITO, FUJIO

× ITO, FUJIO

WEKO 98730

ITO, FUJIO

Search repository
キーワード
主題Scheme Other
主題 Micro-computer
キーワード
主題Scheme Other
主題 Weight balance analyzer
キーワード
主題Scheme Other
主題 Floor reaction force
キーワード
主題Scheme Other
主題 Three-dimensional goniometer
キーワード
主題Scheme Other
主題 Rehabilitation medicine
抄録
内容記述 Analysis of human motion is extremely important in order to obtain fundamental data for training in the field of rehabilitation. At Nagoya University we are analysing human motion by use of a microcomputer to elucidate functional characteristics of the locomotion system. After the introduction of micro-computers, it has become possible to accumulate and integrate more data and process them more quickly and conveniently. Data obtained from the weight balance analyzer, large force plate and three-dimensional goniometer devised by the authors are subjected to on-line processing through an A/D convertor. 1. The weight-balance analyzer for the evaluation of dynamic balance ability can be used both in standing and sitting positions. A computer block-break game is integrated into the program so that training can be performed enjoyably. 2. A large serial force plate is used to detect the floor reaction force of individual legs. Three force components in the directions of X, Y and Z are transformed to resultant force, velocity, acceleration and paths of center of pressure through mathematic processing. 3. The three-dimensinal goniometer describes angular changes of the hip or knee joint in the three planes during walking. In addition to flexion-cxtension, adduction-abduction and internal-external rotation can be grasped easily by this device.
内容記述タイプ Abstract
出版者
出版者 Nagoya University School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.46.1-4.55
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4614/4614.html
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ ISSN
収録物識別子 2186-3326
書誌情報 Nagoya Journal of Medical Science

巻 46, 号 1-4, p. 55-66, 発行日 1984-03
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:15:03.533952
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3