{"created":"2021-03-01T06:26:03.155806+00:00","id":18626,"links":{},"metadata":{"_buckets":{"deposit":"9ae81f67-a0bb-4c48-87f6-73e075cd942c"},"_deposit":{"id":"18626","owners":[],"pid":{"revision_id":0,"type":"depid","value":"18626"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00018626","sets":["673:674:675"]},"author_link":["54148","54149","54150","54151","54152","54153"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"012154","bibliographicPageStart":"012154","bibliographicVolumeNumber":"97","bibliographic_titles":[{"bibliographic_title":"Journal of Physics: Conference Series","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have been developing Superconducting Fault Current Limiting Transformer (SFCLT) with both functions of superconducting transformer and superconducting fault current limiter. As the Step-IV of the SFCLT project, in this paper, we designed, fabricated and tested HTc-SFCLT with 2G YBCO coated conductors to be operated in liquid nitrogen at 77 K. The ratings of the HTc-SFCLT with 2G coated conductors are 3-phase, 100 kVA, 6600 V / 210 V. Especially, the possibility of self-recovery into superconducting state after the fault current limitation was investigated by the simple clearance of the fault, which is very important as a superconducting transformer and for power system operation. The criteria of self-recovery were quantified for different combination of load current before the fault and prospective fault current during the fault.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"8th European Conference on Applied Superconductivity, EUCAS 2007, September 16-20, 2007, Brussels, Belgium","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1088/1742-6596/97/1/012154"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/20718"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/1742-6596/97/1/012154","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Published under licence in Journal of Physics: Conference Series by IOP Publishing Ltd.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1742-6588","subitem_source_identifier_type":"PISSN"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kojima, H","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54148","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ito, S","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54149","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, N","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54150","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, F","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54151","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noe, M","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54152","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, H","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54153","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"1742-6596_97_1_012154.pdf","filesize":[{"value":"2.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1742-6596_97_1_012154.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/18626/files/1742-6596_97_1_012154.pdf"},"version_id":"5aff3182-b545-4b3f-8b97-d2af0bbc51c3"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Self-recovery Characteristics of High-Tc Superconducting Fault Current Limiting Transformer (HTc-SFCLT) with 2G Coated Conductors","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Self-recovery Characteristics of High-Tc Superconducting Fault Current Limiting Transformer (HTc-SFCLT) with 2G Coated Conductors","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-11-06"},"publish_date":"2014-11-06","publish_status":"0","recid":"18626","relation_version_is_last":true,"title":["Self-recovery Characteristics of High-Tc Superconducting Fault Current Limiting Transformer (HTc-SFCLT) with 2G Coated Conductors"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:46:19.655454+00:00"}