{"created":"2021-03-01T06:26:03.415152+00:00","id":18630,"links":{},"metadata":{"_buckets":{"deposit":"b3d977e7-48ab-4c3e-9144-9cf1cdf3d73f"},"_deposit":{"id":"18630","owners":[],"pid":{"revision_id":0,"type":"depid","value":"18630"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00018630","sets":["673:674:675"]},"author_link":["54172","54173","54174","54175","54176","54177"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"1404","bibliographicPageStart":"1401","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have been developing Superconducting Fault Current Limiting Transformer (SFCLT) with the function of both superconducting transformer in steady state and superconducting fault current limiter in fault condition. As the Step-5 of SFCLT project, 2 MVA class HTS-SFCLT using YBCO coated conductors with the ratings of 22 kV/6.6 kV has been developed. One of the important concerns for the development of HTS-SFCLT is the current limiting and recovery characteristics as well as the transformer function. Thus, in this paper, current limitation and recovery tests of the HTS-SFCLT are carried out. The current limiting test have revealed that the HTS-SFCLT exhibits the excellent current limiting function as a superconducting fault current limiter, where the prospective short-circuit current IPRO=784 Apeak is reduced to 34% at the first peak and 18% at the 5th cycles. The HTS-SFCLT has been able to recover into superconducting state immediately after the fault clearance. According to the transition of generated resistance of the HTS-SFCLT, the criteria of recovery into superconducting state are quantified for different combinations of load current before the fault and prospective short-circuit current during the fault.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/TASC.2010.2089413"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/20727"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TASC.2010.2089413","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2011 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kojima, Hiroki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54172","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kotari, Masashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54173","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kito, Toyoaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54174","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, Naoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54175","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hanai, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54176","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, Hitoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54177","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"2.pdf","filesize":[{"value":"317.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/18630/files/2.pdf"},"version_id":"286927cd-022f-441d-be5f-4076dde80e4c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Current limiting operation","subitem_subject_scheme":"Other"},{"subitem_subject":"fault current limiter","subitem_subject_scheme":"Other"},{"subitem_subject":"transformer","subitem_subject_scheme":"Other"},{"subitem_subject":"recovery characteristics","subitem_subject_scheme":"Other"},{"subitem_subject":"YBCO coated conductor","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Current Limiting and Recovery Characteristics of 2 MVA Class Superconducting Fault Current Limiting Transformer (SFCLT)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Current Limiting and Recovery Characteristics of 2 MVA Class Superconducting Fault Current Limiting Transformer (SFCLT)","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-11-07"},"publish_date":"2014-11-07","publish_status":"0","recid":"18630","relation_version_is_last":true,"title":["Current Limiting and Recovery Characteristics of 2 MVA Class Superconducting Fault Current Limiting Transformer (SFCLT)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:46:20.488530+00:00"}