{"created":"2021-03-01T06:26:03.607578+00:00","id":18633,"links":{},"metadata":{"_buckets":{"deposit":"ef8b8993-859d-4ac6-baa7-86f2159eaf1c"},"_deposit":{"id":"18633","owners":[],"pid":{"revision_id":0,"type":"depid","value":"18633"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00018633","sets":["673:674:675"]},"author_link":["54187","54188","54189","54190","54191"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"1425","bibliographicPageStart":"1422","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Superconducting Fault Current Limiting Transformer (SFCLT) is expected to function as superconducting transformer in steady state and superconducting fault current limiter in fault condition. We have designed, fabricated and tested SFCLT with YBCO coated conductors to be operated in liquid nitrogen (LN2) at 77 K and verified its technological feasibility. In this paper, we developed a simulation model to analyze electrical and thermal behaviors of SFCLT by solving the circuit equation and the heat conduction equation. By the use of this simulation model, we could evaluate the transition of resistance and temperature of the YBCO coated conductors during the fault current limitation as well as after the fault clearance, and verified the recovery criteria of SFCLT.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/TASC.2011.2105234"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/20730"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TASC.2011.2105234","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2011 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, N.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54187","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kito, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54188","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kojima, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54189","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hanai, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54190","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54191","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"6.pdf","filesize":[{"value":"483.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"6.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/18633/files/6.pdf"},"version_id":"4920b035-570a-4260-90d6-53cffe28d7ab"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"YBCO coated conductor","subitem_subject_scheme":"Other"},{"subitem_subject":"superconducting fault current limiter","subitem_subject_scheme":"Other"},{"subitem_subject":"superconducting transformer","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Analysis of Current Limiting and Recovery Characteristics of Superconducting Fault Current Limiting Transformer (SFCLT) with YBCO Coated Conductors","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Analysis of Current Limiting and Recovery Characteristics of Superconducting Fault Current Limiting Transformer (SFCLT) with YBCO Coated Conductors","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-11-07"},"publish_date":"2014-11-07","publish_status":"0","recid":"18633","relation_version_is_last":true,"title":["Analysis of Current Limiting and Recovery Characteristics of Superconducting Fault Current Limiting Transformer (SFCLT) with YBCO Coated Conductors"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:46:27.560757+00:00"}