{"created":"2021-03-01T06:26:03.927627+00:00","id":18638,"links":{},"metadata":{"_buckets":{"deposit":"81940aab-5ec2-4a28-8b72-3a3b63504feb"},"_deposit":{"id":"18638","owners":[],"pid":{"revision_id":0,"type":"depid","value":"18638"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00018638","sets":["673:674:675"]},"author_link":["54211","54212","54213"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"557","bibliographicPageStart":"550","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Dielectrics and Electrical Insulation","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper discusses a novel estimation method for partial discharge inception voltage (PDIV) of magnet wire under inverter surge voltage application. We focused on the generation probability of initial electrons, which induce PD under high electric field and short rise time of surge voltage, by means of Volume-Time theory. We applied the Volume-Time theory to PD inception phenomena in a wedge-shaped air gap of twisted pair samples composed of enameled wires, and estimated PDIV in consideration of initial electron generation probability with temporal and spatial change in electric field distribution. We could estimate PDIV under different waveforms of applied surge voltage for different specifications of enameled wires. PDIV estimated by the extended Volume-Time theory agreed well with the measured PDIV. The estimated PDIV decreased with the increase in the rise time of applied voltage waveform, which corresponded to the V-t characteristics in the time range of inverter surge voltage.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://dx.doi.org/10.1109/TDEI.2012.6180249"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/20735"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TDEI.2012.6180249","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1070-9878","subitem_source_identifier_type":"PISSN"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, Naoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimizu, Fuminobu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54212","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, Hitoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"54213","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"12.pdf","filesize":[{"value":"625.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"12.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/18638/files/12.pdf"},"version_id":"6ae5b7eb-54be-4ebe-8e4f-22d590d101fc"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Inverter surge","subitem_subject_scheme":"Other"},{"subitem_subject":"Partial discharge (PD)","subitem_subject_scheme":"Other"},{"subitem_subject":"PD inception voltage (PDIV)","subitem_subject_scheme":"Other"},{"subitem_subject":"Initial electron","subitem_subject_scheme":"Other"},{"subitem_subject":"Discharge generation probability","subitem_subject_scheme":"Other"},{"subitem_subject":"Volume-Time theory","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Estimation of partial discharge inception voltage of magnet wires under inverter surge voltage by volume-time theory","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Estimation of partial discharge inception voltage of magnet wires under inverter surge voltage by volume-time theory","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-11-07"},"publish_date":"2014-11-07","publish_status":"0","recid":"18638","relation_version_is_last":true,"title":["Estimation of partial discharge inception voltage of magnet wires under inverter surge voltage by volume-time theory"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:07:27.406846+00:00"}