{"_buckets": {"deposit": "28f65ba6-2d94-4358-a1e5-02eeadf8e929"}, "_deposit": {"id": "19461", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "19461"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00019461", "sets": []}, "author_link": ["56945", "56946", "56947", "56948", "56949", "56950"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "PORTABLE ATMOSPHERICS WAVEFORM RECORDER", "subitem_alternative_title_language": "en"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1953-03-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "47", "bibliographicPageStart": "43", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "空電研究所報告", "bibliographic_titleLang": "ja"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The atmospherics waveform recorder of new design was devised,by taking into consideration of transportation. General idea of this equipment followed mainly the former one reported in previous papers. The induced voltage upon the receiving aerial is amplified by a shunt peaking circiut, and the cathode-ray tube is employed to draw the waveforms of atmospherics, and records are made upon films. The time axis in cathode-ray tube is supplied by a condenser and resistance chraging process whose time sweep is 1 ms,6 ms,12 ms,and 16 ms. This apparatus is designed to be devided into five parts for the benefit of transportation.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/21523"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "名古屋大学空電研究所", "subitem_publisher_language": "ja"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0465-7756", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岩井, 章", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "56945", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊藤, 吉之助", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "56946", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村田, 友司", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "56947", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IWAI, Akira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "56948", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ITO, Kichinosuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "56949", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MURATA, Tomoji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "56950", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "bulria_3_1-2_43.pdf", "filesize": [{"value": "910.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 910100.0, "url": {"label": "bulria_3_1-2_43.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/19461/files/bulria_3_1-2_43.pdf"}, "version_id": "01fcf258-d9dd-43f3-b149-fcfa886ccfbb"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "携帶用空電波形測定機", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "携帶用空電波形測定機", "subitem_title_language": "ja"}]}, "item_type_id": "9", "owner": "1", "path": ["1693"], "permalink_uri": "http://hdl.handle.net/2237/21523", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2015-04-09"}, "publish_date": "2015-04-09", "publish_status": "0", "recid": "19461", "relation": {}, "relation_version_is_last": true, "title": ["携帶用空電波形測定機"], "weko_shared_id": -1}
携帶用空電波形測定機
http://hdl.handle.net/2237/21523
http://hdl.handle.net/2237/2152398cb1f79-93ae-4238-a479-90970bce36ee
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-04-09 | |||||
タイトル | ||||||
タイトル | 携帶用空電波形測定機 | |||||
言語 | ja | |||||
その他のタイトル | ||||||
その他のタイトル | PORTABLE ATMOSPHERICS WAVEFORM RECORDER | |||||
言語 | en | |||||
著者 |
岩井, 章
× 岩井, 章× 伊藤, 吉之助× 村田, 友司× IWAI, Akira× ITO, Kichinosuke× MURATA, Tomoji |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
抄録 | ||||||
内容記述 | The atmospherics waveform recorder of new design was devised,by taking into consideration of transportation. General idea of this equipment followed mainly the former one reported in previous papers. The induced voltage upon the receiving aerial is amplified by a shunt peaking circiut, and the cathode-ray tube is employed to draw the waveforms of atmospherics, and records are made upon films. The time axis in cathode-ray tube is supplied by a condenser and resistance chraging process whose time sweep is 1 ms,6 ms,12 ms,and 16 ms. This apparatus is designed to be devided into five parts for the benefit of transportation. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | ja | |||||
出版者 | 名古屋大学空電研究所 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0465-7756 | |||||
書誌情報 |
ja : 空電研究所報告 巻 3, 号 1-2, p. 43-47, 発行日 1953-03-25 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/21523 | |||||
識別子タイプ | HDL |