{"created":"2021-03-01T06:27:01.883161+00:00","id":19529,"links":{},"metadata":{"_buckets":{"deposit":"fa7ae381-4f7a-4ea8-9d8c-d1fbd0c5233d"},"_deposit":{"id":"19529","owners":[],"pid":{"revision_id":0,"type":"depid","value":"19529"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00019529","sets":["879:1183:1640:1698"]},"author_link":["57068","57069","57070"],"item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1956-01-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"74","bibliographicPageStart":"69","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"Proceedings of the Research Institute of Atmospherics, Nagoya University","bibliographic_titleLang":"en"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Last summer, direct comparisons among eleven lightning flash counters of various types concerning the receiving frequency ranges and gains were made at Maebashi. The results obtained are discussed and compared with the data of visual and aural observations at meteorological observatories. Sufficient data on observation to restrict the counting radius within 20 km, as recommended by C. C. I. R. have not yet been obtained, but some results suggest that instruments available for a suitable frequency range and gain, especially a wide band of frequencies in the V. L. F. range, can be used to restrict the counting radius within 20 km. Design details of more suitable and convenient instruments for the purpose are left to future study.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_9_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/21565"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Research Institute of Atmospherics, Nagoya University","subitem_publisher_language":"en"}]},"item_9_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_9_source_id_7":{"attribute_name":"ISSN(print)","attribute_value_mlt":[{"subitem_source_identifier":"0077-264X","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"ITO, KICHINOSUKE","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"57068","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KATO, TOSHIO","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"57069","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"IWAI, AKIRA","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"57070","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"Vol3-7.pdf","filesize":[{"value":"986.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Vol3-7.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/19529/files/Vol3-7.pdf"},"version_id":"da12ccd6-3b1f-4745-9e80-977a810a6ab8"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"LOCAL LIGHTNING FLASH COUNTER WITHIN 20 KM","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"LOCAL LIGHTNING FLASH COUNTER WITHIN 20 KM","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["1698"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2015-04-16"},"publish_date":"2015-04-16","publish_status":"0","recid":"19529","relation_version_is_last":true,"title":["LOCAL LIGHTNING FLASH COUNTER WITHIN 20 KM"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-26T04:36:19.766086+00:00"}