{"created":"2021-03-01T06:27:13.551992+00:00","id":19710,"links":{},"metadata":{"_buckets":{"deposit":"50e6cd2b-b6db-4d1b-9fa8-64b1a5f5bc2c"},"_deposit":{"id":"19710","owners":[],"pid":{"revision_id":0,"type":"depid","value":"19710"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00019710","sets":["879:1183:1689:1717"]},"author_link":["57607","57608","57609","57610","57611","57612"],"item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"STUDIES OF THE LIGHTNING DISCHARGES PART II. ON THE CLOUD DISCHARGE PRECEDING TO A GROUND STROKE","subitem_alternative_title_language":"en"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1959-03-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-2","bibliographicPageEnd":"6","bibliographicPageStart":"1","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"空電研究所報告","bibliographic_titleLang":"ja"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this paper the beginning stage of a ground discharge is investigated mainly on the record of mill type field meter and the following results are obtained. It has reported by Clarence and Malan that a ground discharge usually has the \"preliminary discharge\" - the B field change according to their notation -, which takes place between negative charge in thundercloud and positive charge in lower part of it and leads to a return stroke. In more than 50% cases of the ground discharges recorded by authors observations, they each have a cloud discharge before the preliminary discharge. The cloud discharge neutralizes a part of main negative charge in the cloud and its duration is roughly within 500 ms. In some period of a thunder-storm, this type of ground discharge predominates over the cloud-discharge-less type, but in an other period of it, it reverses. It seems probable to infer that the cloud discharge discussed in this paper concerns a stage in a thunder-storm activity.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_9_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/21756"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"名古屋大学空電研究所","subitem_publisher_language":"ja"}]},"item_9_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_9_source_id_7":{"attribute_name":"ISSN(print)","attribute_value_mlt":[{"subitem_source_identifier":"0465-7756","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"竹内, 利雄","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"57607","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 晴治","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"57608","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高木, 増美","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"57609","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"TAKEUCHI, Toshio","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"57610","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ISHIKAWA, Haruzi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"57611","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"TAKAGI, Masumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"57612","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"bulria_9_1-2_1.pdf","filesize":[{"value":"987.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"bulria_9_1-2_1.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/19710/files/bulria_9_1-2_1.pdf"},"version_id":"f9f3d7f0-cd21-46bb-909e-8da4c5af7fcc"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"雷放電の研究(第2報) : 落雷に先行する放電","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"雷放電の研究(第2報) : 落雷に先行する放電","subitem_title_language":"ja"}]},"item_type_id":"9","owner":"1","path":["1717"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2015-04-30"},"publish_date":"2015-04-30","publish_status":"0","recid":"19710","relation_version_is_last":true,"title":["雷放電の研究(第2報) : 落雷に先行する放電"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-26T06:53:11.685873+00:00"}