ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "97cb30a1-f511-4532-8844-805e43c7250c"}, "_deposit": {"id": "19729", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "19729"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00019729", "sets": []}, "author_link": ["57658", "57659", "57660", "57661", "57662", "57663"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "STUDIES OF THE LIGHTNING DISCHARGES PART IV THE COINCIDENT OBSERVATION OF GROUND DISCHARGES AT TWO PLACES", "subitem_alternative_title_language": "en"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1961-06-15", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "29", "bibliographicPageStart": "27", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "空電研究所報告", "bibliographic_titleLang": "ja"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have obtained four sets of pairs of electrostatic field change records produced by ground discharges through the coincident observations at two places, Maebashi and Shibukawa, which are 13km apart. Though the number of data suited for the present investigation are only four, the following results have been obtained. 1) A pre-preliminary discharge was observed to have occurred at a place in a thundercloud, away from the portion just above the struck point on the ground. 2) The height of the negative charge of the concerned ground stroke was about 3 km in one case. 3) It has been found that the data of the time interval between the two successively recorded ground strokes are to be divided into three groups. The first group has the time interval of less than 600 ms and is due to stroke pairs each of which belongs to the same discharge. The second group has the time interval ranging from 600 ms to 3 sec, and seldom occurs. The third group has the time interval longer than 3 sec, and the interval corresponds to the recovery time of the negative charge dissipated by the preceding stroke of a stroke pair.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/21775"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "名古屋大学空電研究所", "subitem_publisher_language": "ja"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0465-7756", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "竹内, 利雄", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "57658", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 晴治", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "57659", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高木, 増美", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "57660", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takeuti, Tosio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "57661", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Isikawa, Haruzi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "57662", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takagi, Masumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "57663", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "bulria_11_1-2_27.pdf", "filesize": [{"value": "484.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 484000.0, "url": {"label": "bulria_11_1-2_27.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/19729/files/bulria_11_1-2_27.pdf"}, "version_id": "a619fae7-8f47-4791-a79e-98c628067daf"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "雷放電の研究(第4報) : 二地点における落雷の同時観測の結果について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "雷放電の研究(第4報) : 二地点における落雷の同時観測の結果について", "subitem_title_language": "ja"}]}, "item_type_id": "9", "owner": "1", "path": ["1719"], "permalink_uri": "http://hdl.handle.net/2237/21775", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2015-04-30"}, "publish_date": "2015-04-30", "publish_status": "0", "recid": "19729", "relation": {}, "relation_version_is_last": true, "title": ["雷放電の研究(第4報) : 二地点における落雷の同時観測の結果について"], "weko_shared_id": -1}
  1. F300 宇宙地球環境研究所
  2. F300b 紀要
  3. 空電研究所報告
  4. 11(1-2)

雷放電の研究(第4報) : 二地点における落雷の同時観測の結果について

http://hdl.handle.net/2237/21775
http://hdl.handle.net/2237/21775
490eb3b5-f300-4dfd-817d-a0172fcc7055
名前 / ファイル ライセンス アクション
bulria_11_1-2_27.pdf bulria_11_1-2_27.pdf (484.0 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2015-04-30
タイトル
タイトル 雷放電の研究(第4報) : 二地点における落雷の同時観測の結果について
言語 ja
その他のタイトル
その他のタイトル STUDIES OF THE LIGHTNING DISCHARGES PART IV THE COINCIDENT OBSERVATION OF GROUND DISCHARGES AT TWO PLACES
言語 en
著者 竹内, 利雄

× 竹内, 利雄

WEKO 57658

ja 竹内, 利雄

Search repository
石川, 晴治

× 石川, 晴治

WEKO 57659

ja 石川, 晴治

Search repository
高木, 増美

× 高木, 増美

WEKO 57660

ja 高木, 増美

Search repository
Takeuti, Tosio

× Takeuti, Tosio

WEKO 57661

en Takeuti, Tosio

Search repository
Isikawa, Haruzi

× Isikawa, Haruzi

WEKO 57662

en Isikawa, Haruzi

Search repository
Takagi, Masumi

× Takagi, Masumi

WEKO 57663

en Takagi, Masumi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
抄録
内容記述 We have obtained four sets of pairs of electrostatic field change records produced by ground discharges through the coincident observations at two places, Maebashi and Shibukawa, which are 13km apart. Though the number of data suited for the present investigation are only four, the following results have been obtained. 1) A pre-preliminary discharge was observed to have occurred at a place in a thundercloud, away from the portion just above the struck point on the ground. 2) The height of the negative charge of the concerned ground stroke was about 3 km in one case. 3) It has been found that the data of the time interval between the two successively recorded ground strokes are to be divided into three groups. The first group has the time interval of less than 600 ms and is due to stroke pairs each of which belongs to the same discharge. The second group has the time interval ranging from 600 ms to 3 sec, and seldom occurs. The third group has the time interval longer than 3 sec, and the interval corresponds to the recovery time of the negative charge dissipated by the preceding stroke of a stroke pair.
言語 en
内容記述タイプ Abstract
出版者
言語 ja
出版者 名古屋大学空電研究所
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0465-7756
書誌情報 ja : 空電研究所報告

巻 11, 号 1-2, p. 27-29, 発行日 1961-06-15
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/21775
識別子タイプ HDL
戻る
0