WEKO3
AND
アイテム
{"_buckets": {"deposit": "5fc1d50b-2d44-465a-8a06-4c3e3c74ff3b"}, "_deposit": {"id": "19755", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "19755"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00019755"}, "item_9_alternative_title_19": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u8a00\u8a9e\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "SOME RESULTS AS TO THUNDERSTORM MECHANISM OBTAINED BY SIMULTANEOUS OBSERVATIONS AT SOME PLACES"}]}, "item_9_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1963-03-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "6", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{"bibliographic_title": "\u7a7a\u96fb\u7814\u7a76\u6240\u5831\u544a"}]}]}, "item_9_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "Simultaneous observations of thunderstorms at some places in Gunma prefecture have been carried since 1960. We obtained till now some results as following. A thundercloud consists of two vertical electric dipoles which have reversal senses each other and those two dipoles are horizontally apart a few kilometers from each other. Some of cloud discharges occur within one of those dipoles. Some of other cloud discharges neutralize one of those dipoles and the other successively. A few cloud discharges occur at other portions. The P-P discharge - the cloud discharge preceding ground discharge - occurs within upper positive dipole and successive ground discharge concerns upper negative dipole. Some records show that field changes due to ground strokes decrease those inclinations when distances between observation point and struck point increase. This cause does not clear.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/21801"}]}, "item_9_publisher_32": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u540d\u53e4\u5c4b\u5927\u5b66\u7a7a\u96fb\u7814\u7a76\u6240"}]}, "item_9_select_15": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN\uff08print\uff09", "attribute_value_mlt": [{"subitem_source_identifier": "0465-7756", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u7af9\u5185, \u5229\u96c4"}], "nameIdentifiers": [{"nameIdentifier": "57731", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u9ad8\u6728, \u5897\u7f8e"}], "nameIdentifiers": [{"nameIdentifier": "57732", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKEUTI, Tosio"}], "nameIdentifiers": [{"nameIdentifier": "57733", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKAGI, Masumi"}], "nameIdentifiers": [{"nameIdentifier": "57734", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "bulria_13_1-2_1.pdf", "filesize": [{"value": "913.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 913400.0, "url": {"label": "bulria_13_1-2_1.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/19755/files/bulria_13_1-2_1.pdf"}, "version_id": "7d3d31ab-1675-4d2a-a922-1595ef01ff20"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u96f7\u653e\u96fb\u306e\u591a\u70b9\u540c\u6642\u89b3\u6e2c\u306e\u7d50\u679c\u306b\u3064\u3044\u3066", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u96f7\u653e\u96fb\u306e\u591a\u70b9\u540c\u6642\u89b3\u6e2c\u306e\u7d50\u679c\u306b\u3064\u3044\u3066"}]}, "item_type_id": "9", "owner": "1", "path": ["879/1183/1689/1723"], "permalink_uri": "http://hdl.handle.net/2237/21801", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2015-05-07"}, "publish_date": "2015-05-07", "publish_status": "0", "recid": "19755", "relation": {}, "relation_version_is_last": true, "title": ["\u96f7\u653e\u96fb\u306e\u591a\u70b9\u540c\u6642\u89b3\u6e2c\u306e\u7d50\u679c\u306b\u3064\u3044\u3066"], "weko_shared_id": null}
雷放電の多点同時観測の結果について
http://hdl.handle.net/2237/21801
90321dfb-9f2f-438b-8542-8fa80517a67f
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-05-07 | |||||
タイトル | ||||||
タイトル | 雷放電の多点同時観測の結果について | |||||
その他のタイトル | ||||||
その他のタイトル | SOME RESULTS AS TO THUNDERSTORM MECHANISM OBTAINED BY SIMULTANEOUS OBSERVATIONS AT SOME PLACES | |||||
著者 |
竹内, 利雄
× 竹内, 利雄× 高木, 増美× TAKEUTI, Tosio× TAKAGI, Masumi |
|||||
抄録 | ||||||
内容記述 | Simultaneous observations of thunderstorms at some places in Gunma prefecture have been carried since 1960. We obtained till now some results as following. A thundercloud consists of two vertical electric dipoles which have reversal senses each other and those two dipoles are horizontally apart a few kilometers from each other. Some of cloud discharges occur within one of those dipoles. Some of other cloud discharges neutralize one of those dipoles and the other successively. A few cloud discharges occur at other portions. The P-P discharge - the cloud discharge preceding ground discharge - occurs within upper positive dipole and successive ground discharge concerns upper negative dipole. Some records show that field changes due to ground strokes decrease those inclinations when distances between observation point and struck point increase. This cause does not clear. | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
出版者 | 名古屋大学空電研究所 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
ISSN(print) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0465-7756 | |||||
書誌情報 |
空電研究所報告 巻 13, 号 1-2, p. 1-6, 発行日 1963-03-25 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/21801 | |||||
識別子タイプ | HDL |