{"created":"2022-11-22T05:59:10.170129+00:00","id":2004204,"links":{},"metadata":{"_buckets":{"deposit":"be9d601f-043f-4037-af3b-e2d4743a0422"},"_deposit":{"id":"2004204","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2004204"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:02004204","sets":["499:508:509:1669094631719"]},"author_link":[],"control_number":"2004204","item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"771","bibliographicPageStart":"762","bibliographicVolumeNumber":"84","bibliographic_titles":[{"bibliographic_title":"Nagoya Journal of Medical Science","bibliographic_titleLang":"en"}]}]},"item_9_description_4":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"This study sought to establish an experimental aneurysm model of visualizing coil insertion using radiolucent nylon coils. Moreover, this study aimed to clarify the characteristics and differences of each coil and use them clinically as indices of coil selection. The coil insertion test was performed on the 10 mm spherical silicone aneurysm model filled to a nylon coil volume embolization ratio of 11.8%. Five types of coil were randomly tested six times, and the distribution of the coils was analyzed by fluoroscopy imaging. Indices of “Area (mm2),” “Feret’s diameter (mm),” and “Circularity” were calculated from the fluoroscopic images. Among the indices, only “Area” showed a significant difference between coils (p = 0.002). On multivariate analysis, “Area” of the ED Infini was larger than those of Target XL soft and Galaxy G3 (p = 0.018 and 0.026, respectively). Furthermore, the area of the 360 soft was larger than that of G3 (p = 0.049). Analysis of the correlation between these values and the coil configuration showed that “Area” was negatively correlated with the stock-wire diameter (r = −0.50; p = 0.004) and primary coil configuration (r = −0.65; p < 0.001). When inserting the coils in the early stage, although the difference between each coil is relatively difficult to obtain, knowledge on the proper use of the coils with differences in characteristics can help in selecting the coil most appropriate for the conditions.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18999/nagjms.84.4.762","subitem_identifier_reg_type":"JaLC"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Nagoya University Graduate School of Medicine, School of Medicine","subitem_publisher_language":"en"}]},"item_9_relation_43":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/844.html","subitem_relation_type_select":"URI"}}]},"item_9_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International","subitem_rights_language":"en","subitem_rights_resource":"http://creativecommons.org/licenses/by-nc-nd/4.0/"}]},"item_9_source_id_7":{"attribute_name":"収録物識別子","attribute_value_mlt":[{"subitem_source_identifier":"0027-7622","subitem_source_identifier_type":"PISSN"},{"subitem_source_identifier":"2186-3326","subitem_source_identifier_type":"EISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Goto, Shunsaku","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Izumi, Takashi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Nishihori, Masahiro","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Araki, Yoshio","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Yokoyama, Kinya","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Uda, Kenji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Saito, Ryuta","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2022-11-24"}],"displaytype":"detail","filename":"08_Goto.pdf","filesize":[{"value":"19.1 MB"}],"format":"application/pdf","licensetype":"license_5","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/2004204/files/08_Goto.pdf"},"version_id":"849e69cc-441f-4d1a-85ca-0c8bdc1f09bf"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"filling coil","subitem_subject_scheme":"Other"},{"subitem_subject":"aneurysm model","subitem_subject_scheme":"Other"},{"subitem_subject":"coil distribution","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Efficacy of comparing coil behavior and distribution using the silicone aneurysm model: difference of coil distribution in the early filling stage","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Efficacy of comparing coil behavior and distribution using the silicone aneurysm model: difference of coil distribution in the early filling stage","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"1","path":["1669094631719"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-11-22"},"publish_date":"2022-11-22","publish_status":"0","recid":"2004204","relation_version_is_last":true,"title":["Efficacy of comparing coil behavior and distribution using the silicone aneurysm model: difference of coil distribution in the early filling stage"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-04-28T06:53:36.048961+00:00"}