ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "bfe6508b-e615-4c61-b302-85060877ba78"}, "_deposit": {"created_by": 17, "id": "2004234", "owner": "17", "owners": [17], "owners_ext": {"displayname": "repository", "username": "repository"}, "pid": {"revision_id": 0, "type": "depid", "value": "2004234"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:02004234", "sets": ["501"]}, "author_link": [], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_1629683748249": {"attribute_name": "日付", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2023-10-01", "subitem_date_issued_type": "Available"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "873", "bibliographicPageStart": "863", "bibliographicVolumeNumber": "27", "bibliographic_titles": [{"bibliographic_title": "Respirology", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Background and objective: Bronchoscopy is an airborne particle-generating procedure. However, few methods for safe bronchoscopy have been developed. To reduce airborne particles during bronchoscopy, we created an ‘e-mask’, which is a simple, disposable mask for patients. Our objective was to evaluate the e-mask\u0027s protective ability against airborne particles and to assess respiratory adverse events and complications. Methods: Patients with stage 2–4 chronic obstructive pulmonary disease were excluded. We performed visualization and quantifying experiments on airborne particles with and without the e-mask. We prospectively evaluated whether wearing the e-mask during bronchoscopy was associated with the incidence of patients requiring \u003e5 L/min oxygen to maintain \u003e90% oxygen saturation, and patients with \u003e45 mm Hg end-tidal carbon dioxide (EtCO2) elevation, in addition to complications, compared to historical controls. Results: In the visualization experiment, more than ten thousand times of airborne particles were generated without the e-mask than with the e-mask. The volume of airborne particles was significantly reduced with the e-mask, compared to that without the e-mask (p = 0.011). Multivariate logistic regression analysis revealed that wearing the e-mask had no significant effect on the incidence of patients requiring \u003e5 L/min oxygen to maintain \u003e90% oxygen saturation, (p = 0.959); however, wearing the e-mask was a significant factor in \u003e45 mm Hg EtCO2 elevation (p = 0.026). No significant differences in complications were observed between the e-mask and control groups (5.8% vs. 2.5%, p = 0.395). Conclusion: Wearing the e-mask during bronchoscopy significantly reduced the generation of airborne particles during bronchoscopy without increasing complications.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1111/resp.14321", "subitem_relation_type_select": "DOI"}}]}, "item_9_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "\"This is the peer reviewed version of the following article: [ Ito, T, Okachi, S, Sato, K, Yasui, H, Fukatsu, N, Ando, M, et al. Prevention of droplet dispersal with ‘e-mask’: A new daily use endoscopic mask during bronchoscopy. Respirology. 2022; 27(10): 863–873. https://doi.org/10.1111/resp.14321], which has been published in final form at [https://doi.org/10.1111/resp.14321]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited.\"", "subitem_rights_language": "en"}]}, "item_9_source_id_7": {"attribute_name": "収録物識別子", "attribute_value_mlt": [{"subitem_source_identifier": "1323-7799", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "embargoed access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_f1cf"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ito, Takayasu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Okachi, Shotaro", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Sato, Kazuhide", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Yasui, Hirotoshi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Fukatsu, Noriaki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ando, Masahiko", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Chen‐Yoshikawa, Toyofumi Fengshi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Saka, Hideo", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2023-10-01"}], "displaytype": "detail", "download_preview_message": "Download / Preview is available from 2023/9/30.", "file_order": 0, "filename": "20221129_nagoya_univ_repository.pdf", "filesize": [{"value": "6.5 MB"}], "format": "application/pdf", "future_date_message": "Download is available from 2023/9/30.", "is_thumbnail": false, "mimetype": "application/pdf", "size": 6500000.0, "url": {"objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/2004234/files/20221129_nagoya_univ_repository.pdf"}, "version_id": "d7f13577-4ae7-458b-9d5e-b730440afc51"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Prevention of droplet dispersal with ‘e‐mask’: A new daily use endoscopic mask during bronchoscopy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Prevention of droplet dispersal with ‘e‐mask’: A new daily use endoscopic mask during bronchoscopy", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "17", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/0002004234", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2022-11-30"}, "publish_date": "2022-11-30", "publish_status": "0", "recid": "2004234", "relation": {}, "relation_version_is_last": true, "title": ["Prevention of droplet dispersal with ‘e‐mask’: A new daily use endoscopic mask during bronchoscopy"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100a 雑誌掲載論文
  3. 学術雑誌

Prevention of droplet dispersal with ‘e‐mask’: A new daily use endoscopic mask during bronchoscopy

http://hdl.handle.net/2237/0002004234
http://hdl.handle.net/2237/0002004234
bac4438d-44dc-407a-bd83-8aaeb9b0a6ee
名前 / ファイル ライセンス アクション
20221129_nagoya_univ_repository.pdf 20221129_nagoya_univ_repository.pdf (6.5 MB)
 Download is available from 2023/9/30.
Item type itemtype_ver1(1)
公開日 2022-11-30
タイトル
タイトル Prevention of droplet dispersal with ‘e‐mask’: A new daily use endoscopic mask during bronchoscopy
言語 en
著者 Ito, Takayasu

× Ito, Takayasu

en Ito, Takayasu

Search repository
Okachi, Shotaro

× Okachi, Shotaro

en Okachi, Shotaro

Search repository
Sato, Kazuhide

× Sato, Kazuhide

en Sato, Kazuhide

Search repository
Yasui, Hirotoshi

× Yasui, Hirotoshi

en Yasui, Hirotoshi

Search repository
Fukatsu, Noriaki

× Fukatsu, Noriaki

en Fukatsu, Noriaki

Search repository
Ando, Masahiko

× Ando, Masahiko

en Ando, Masahiko

Search repository
Chen‐Yoshikawa, Toyofumi Fengshi

× Chen‐Yoshikawa, Toyofumi Fengshi

en Chen‐Yoshikawa, Toyofumi Fengshi

Search repository
Saka, Hideo

× Saka, Hideo

en Saka, Hideo

Search repository
アクセス権
アクセス権 embargoed access
アクセス権URI http://purl.org/coar/access_right/c_f1cf
権利
言語 en
権利情報 "This is the peer reviewed version of the following article: [ Ito, T, Okachi, S, Sato, K, Yasui, H, Fukatsu, N, Ando, M, et al. Prevention of droplet dispersal with ‘e-mask’: A new daily use endoscopic mask during bronchoscopy. Respirology. 2022; 27(10): 863–873. https://doi.org/10.1111/resp.14321], which has been published in final form at [https://doi.org/10.1111/resp.14321]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited."
内容記述
内容記述 Background and objective: Bronchoscopy is an airborne particle-generating procedure. However, few methods for safe bronchoscopy have been developed. To reduce airborne particles during bronchoscopy, we created an ‘e-mask’, which is a simple, disposable mask for patients. Our objective was to evaluate the e-mask's protective ability against airborne particles and to assess respiratory adverse events and complications. Methods: Patients with stage 2–4 chronic obstructive pulmonary disease were excluded. We performed visualization and quantifying experiments on airborne particles with and without the e-mask. We prospectively evaluated whether wearing the e-mask during bronchoscopy was associated with the incidence of patients requiring >5 L/min oxygen to maintain >90% oxygen saturation, and patients with >45 mm Hg end-tidal carbon dioxide (EtCO2) elevation, in addition to complications, compared to historical controls. Results: In the visualization experiment, more than ten thousand times of airborne particles were generated without the e-mask than with the e-mask. The volume of airborne particles was significantly reduced with the e-mask, compared to that without the e-mask (p = 0.011). Multivariate logistic regression analysis revealed that wearing the e-mask had no significant effect on the incidence of patients requiring >5 L/min oxygen to maintain >90% oxygen saturation, (p = 0.959); however, wearing the e-mask was a significant factor in >45 mm Hg EtCO2 elevation (p = 0.026). No significant differences in complications were observed between the e-mask and control groups (5.8% vs. 2.5%, p = 0.395). Conclusion: Wearing the e-mask during bronchoscopy significantly reduced the generation of airborne particles during bronchoscopy without increasing complications.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 Wiley
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1111/resp.14321
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 1323-7799
書誌情報 en : Respirology

巻 27, 号 10, p. 863-873, 発行日 2022-10
ファイル公開日
日付 2023-10-01
日付タイプ Available
戻る
0
views
See details
Views

Versions

Ver.1 2022-11-30 02:24:23.179836
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3