| アイテムタイプ |
itemtype_ver1(1) |
| 公開日 |
2024-10-18 |
| タイトル |
|
|
タイトル |
A prospective study on the histological evaluation of type 1 autoimmune pancreatitis using endoscopic ultrasound‐guided fine needle biopsy with a 19‐gauge Franseen needle |
|
言語 |
en |
| 著者 |
Ishikawa, Takuya
Yamao, Kentaro
Mizutani, Yasuyuki
Iida, Tadashi
Uetsuki, Kota
Shimoyama, Yoshie
Nakamura, Masanao
Furukawa, Kazuhiro
Yamamura, Takeshi
Kawashima, Hiroki
|
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 権利 |
|
|
権利情報 |
"This is the peer reviewed version of the following article: [Ishikawa T, Yamao K, Mizutani Y, Iida T, Uetsuki K, Shimoyama Y, et al. A prospective study on the histological evaluation of type 1 autoimmune pancreatitis using endoscopic ultrasound-guided fine needle biopsy with a 19-gauge Franseen needle. J Hepatobiliary Pancreat Sci. 2024; 31: 581–590. https://doi.org/10.1002/jhbp.1438], which has been published in final form at [https://doi.org/10.1002/jhbp.1438]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited." |
|
言語 |
en |
| 内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Background/Purpose: To assess the diagnostic efficacy and safety of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) using a 19-gauge Franseen needle for autoimmune pancreatitis (AIP). Methods: Twenty patients suspected of having type 1 AIP were prospectively enrolled and underwent EUS-FNB with a 19-gauge Franseen needle. Their data were compared with those of historical controls: a total of 29 type 1 AIP patients had EUS-FNB with a 22-gauge Franseen needle. Results: Specimens suitable for histological evaluation were obtained from 19 of the 20 patients (95%), and the median total tissue area was 11.9 mm2. The histological diagnosis rate of AIP was 65% (95% CI: 43.2%–82%). Adverse events were observed in three patients (15%), and a switch to 22-gauge needles occurred during transduodenal puncture in two patients. Compared to those punctured with 22-gauge needles, patients punctured with 19-gauge needles had greater prevalence of each characteristic feature of lymphoplasmacytic sclerosing pancreatitis, but the difference was not statistically significant. Conclusions: EUS-FNB using a 19-gauge Franseen needle demonstrated favorable performance for the histological diagnosis of AIP and allowed for large tissue samples, potentially facilitating pathological diagnosis. However, during transduodenal puncture, maneuverability is reduced; therefore, the needle may need to be selected according to the puncture site. |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
Elsevier |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプresource |
http://purl.org/coar/resource_type/c_6501 |
|
タイプ |
journal article |
| 出版タイプ |
|
|
出版タイプ |
AM |
|
出版タイプResource |
http://purl.org/coar/version/c_ab4af688f83e57aa |
| 関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.1002/jhbp.1438 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
1868-6974 |
| 書誌情報 |
en : Journal of Hepato-Biliary-Pancreatic Sciences
巻 31,
号 8,
p. 581-590,
発行日 2024-08
|
| ファイル公開日 |
|
|
日付 |
2025-08-01 |
|
日付タイプ |
Available |