Endoscope-assisted brain tumor removal overcomes the restriction of using intraoperative open magnetic resonance imaging in the suboccipital approach

https://doi.org/10.18999/nagjms.87.1.168
https://doi.org/10.18999/nagjms.87.1.168
6debf28f-e890-4d3f-b17c-09a1ba13a09c
名前 / ファイル ライセンス アクション
16_Sasaki.pdf 16_Sasaki.pdf (12.8 MB)
license.icon
アイテムタイプ itemtype_ver1(1)
公開日 2025-03-04
タイトル
タイトル Endoscope-assisted brain tumor removal overcomes the restriction of using intraoperative open magnetic resonance imaging in the suboccipital approach
言語 en
著者 Sasaki, Kei

× Sasaki, Kei

en Sasaki, Kei

Search repository
Ohka, Fumiharu

× Ohka, Fumiharu

en Ohka, Fumiharu

Search repository
Motomura, Kazuya

× Motomura, Kazuya

en Motomura, Kazuya

Search repository
Nagata, Yuichi

× Nagata, Yuichi

en Nagata, Yuichi

Search repository
Takeuchi, Kazuhito

× Takeuchi, Kazuhito

en Takeuchi, Kazuhito

Search repository
Saito, Ryuta

× Saito, Ryuta

en Saito, Ryuta

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
言語 en
キーワード
主題Scheme Other
主題 intraoperative MRI
キーワード
主題Scheme Other
主題 positioning
キーワード
主題Scheme Other
主題 multimodality
キーワード
主題Scheme Other
主題 endoscope
内容記述
内容記述タイプ Abstract
内容記述 Intraoperative magnetic resonance imaging (iMRI) plays a crucial role in improving the precision of brain tumor surgeries. However, the use of iMRI can impose certain limitations on intraoperative head positioning. In regular microscopic surgery, head positioning is of utmost importance because an appropriate surgical field is important for the efficacy and safety of surgery. Therefore, in cases where adequate head positioning is difficult, usually, iMRI will not be utilized. Herein, we report an adult case of cerebellar astrocytoma whose tumor extended to the culmen of the cerebellum. Upon surgery via the suboccipital approach, the positional limitations imposed by iMRI led to an insufficient vertex-down position and limited surgical field, which hampered the removal of the upper portion of the tumor. However, this concern could be overcome when used in combination with an endoscope. The potential of iMRI applications is anticipated to be enhanced by overcoming positional limitations through combined endoscopic surgery. The use of multimodality in surgery is an optimal example of how surgical support equipment can also improve surgical outcomes. Here, we report on the new possibilities offered by multimodality.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.87.1.168
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/871.html
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0027-7622
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 87, 号 1, p. 168-172, 発行日 2025-02
戻る
0
views
See details
Views

Versions

Ver.1 2025-03-04 01:24:53.101327
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3