ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B100 理学部/理学研究科
  2. B100a 雑誌掲載論文
  3. 学術雑誌

Characterization of birefringence inhomogeneity of KAGRA sapphire mirrors from transmitted wavefront error measurements

http://hdl.handle.net/2237/0002012816
http://hdl.handle.net/2237/0002012816
a720be29-323c-4b42-98f4-7fbf967b91d0
名前 / ファイル ライセンス アクション
PhysRevD_110_082007.pdf PhysRevD_110_082007.pdf (2.6 MB)
アイテムタイプ itemtype_ver1(1)
公開日 2025-06-03
タイトル
タイトル Characterization of birefringence inhomogeneity of KAGRA sapphire mirrors from transmitted wavefront error measurements
言語 en
著者 Wang, Haoyu

× Wang, Haoyu

en Wang, Haoyu

Search repository
Aso, Yoichi

× Aso, Yoichi

en Aso, Yoichi

Search repository
Leonardi, Matteo

× Leonardi, Matteo

en Leonardi, Matteo

Search repository
Eisenmann2, Marc

× Eisenmann2, Marc

en Eisenmann2, Marc

Search repository
Hirose, Eiichi

× Hirose, Eiichi

en Hirose, Eiichi

Search repository
Billingsley, GariLynn

× Billingsley, GariLynn

en Billingsley, GariLynn

Search repository
Kokeyama, Keiko

× Kokeyama, Keiko

en Kokeyama, Keiko

Search repository
Ushiba, Takafumi

× Ushiba, Takafumi

en Ushiba, Takafumi

Search repository
Tamaki, Masahide

× Tamaki, Masahide

en Tamaki, Masahide

Search repository
Michimura, Yuta

× Michimura, Yuta

en Michimura, Yuta

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報 © 2024 American Physical Society
言語 en
内容記述
内容記述タイプ Abstract
内容記述 Cooling down test masses to cryogenic temperatures is a way to reduce the thermal noise of gravitational wave detectors. Crystalline materials are considered the most promising materials for fabricating cryogenic test masses and their coatings because of their excellent thermal and optical properties at low temperatures. However, birefringence owing to local impurities and inhomogeneities in the crystal can degrade the performance of the detector. The birefringence measurement or mapping over a two-dimensional area is thus important. This study describes a method for fast birefringence measurements of a large sample by simply combining a series of transmission wavefront error measurements using linearly polarized light with Fizeau interferometers. Using this method, the birefringence inhomogeneity information of KAGRA’s two input test masses with a diameter of 22 cm was fully reconstructed. The birefringence information was then used to calculate the transverse beam shapes of the light fields in orthogonal polarization directions when passing through the substrate. It was possible to find a calculated beam shape consistent with in situ measurements using the KAGRA interferometer. This technique is crucial for birefringence characterization of test masses in future detectors, where even larger sizes are used.
言語 en
出版者
出版者 American Physical Society
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1103/PhysRevD.110.082007
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 2470-0010
書誌情報 en : Physical Review D

巻 110, p. 082007, 発行日 2024-10-18
戻る
0
views
See details
Views

Versions

Ver.1 2025-06-03 06:54:44.392497
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3