ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C100 医学部/医学系研究科
  2. C100b 刊行物
  3. Nagoya journal of medical science
  4. 87(3)

Calcium chloride within carbon dioxide absorbents prevents Compound A production from sevoflurane

https://doi.org/10.18999/nagjms.87.3.392
https://doi.org/10.18999/nagjms.87.3.392
f6b0657a-5e13-4247-8af1-1b5071f1e0f6
名前 / ファイル ライセンス アクション
02_Ando.pdf 02_Ando.pdf (5.1 MB)
license.icon
アイテムタイプ itemtype_ver1(1)
公開日 2024-09-09
タイトル
タイトル Calcium chloride within carbon dioxide absorbents prevents Compound A production from sevoflurane
言語 en
著者 Ando, Takahiro

× Ando, Takahiro

en Ando, Takahiro

Search repository
Mori, Atsushi

× Mori, Atsushi

en Mori, Atsushi

Search repository
Nakatochi, Masahiro

× Nakatochi, Masahiro

en Nakatochi, Masahiro

Search repository
Nishiwaki, Kimitoshi

× Nishiwaki, Kimitoshi

en Nishiwaki, Kimitoshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
言語 en
キーワード
主題Scheme Other
主題 calcium chloride
キーワード
主題Scheme Other
主題 carbon dioxide absorbents
キーワード
主題Scheme Other
主題 Compound A
キーワード
主題Scheme Other
主題 deliquescent
キーワード
主題Scheme Other
主題 sevoflurane
内容記述
内容記述タイプ Abstract
内容記述 Calcium chloride (CaCl2)-containing carbon dioxide (CO2) absorbers are characterized by their ability to produce almost no pentafluoroisopropenyl fluoromethyl ether (Compound A), a potentially nephrotoxic byproduct of sevoflurane, in vitro. However, the precise role of CaCl2 in this process remains unclear. We aimed to clarify the role of CaCl2 in vitro and determine whether CaCl2-containing CO2 absorbents produce Compound A during prolonged surgery under low- and minimal-flow sevoflurane anesthesia using Japanese brand Yabashi Lime-f (YL-f). In vitro, a reaction between 1 L of sevoflurane gas (8%) with 5% CO2 and an absorbent specimen (20 g) with or without water was performed in an artificial closed-circuit system for 15 or 60 min at 45 °C. In vivo, patients scheduled for colorectal resection received 2.0 vol% sevoflurane at fresh gas flows of 2.0, 1.0, or 0.5 L/min (N = 6) with YL-f. Gas samples from the anesthetic circuit were collected 6 h after induction and at the conclusion of surgeries lasting over 7 h. Compound A concentrations were measured using gas chromatography-flame ionization detection. Compound A production was observed in CaCl2-free absorbents but not in those containing CaCl2 in vitro. During 60-min reactions, CaCl2-free YL-f derivatives produced a median 3.5 ppm of Compound A, with higher concentrations (7.1 ppm) observed upon the addition of 3 mL of water. YL-f did not produce Compound A, regardless of the presence of water. Compound A was not detected in in vivo samples. In conclusion, CaCl2 suppresses Compound A production from sevoflurane, likely by trapping water within the anesthetic circuit.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.87.3.392
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/873.html
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0027-7622
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 87, 号 3, p. 392-406, 発行日 2025-08
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-27 05:31:23.552648
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3