ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C100 医学部/医学系研究科
  2. C100b 刊行物
  3. Nagoya journal of medical science
  4. 87(3)

Hemolytic anemia due to a felt strip used in the early stage of acute aortic dissection surgery

https://doi.org/10.18999/nagjms.87.3.590
https://doi.org/10.18999/nagjms.87.3.590
4f4686b7-5234-4db4-b8a1-65b55423ff0f
名前 / ファイル ライセンス アクション
19_Kuwabara.pdf 19_Kuwabara.pdf (17.2 MB)
license.icon
アイテムタイプ itemtype_ver1(1)
公開日 2024-09-09
タイトル
タイトル Hemolytic anemia due to a felt strip used in the early stage of acute aortic dissection surgery
言語 en
著者 Kuwabara, Fumiaki

× Kuwabara, Fumiaki

en Kuwabara, Fumiaki

Search repository
Yano, Daisuke

× Yano, Daisuke

en Yano, Daisuke

Search repository
Mashiko, Yuji

× Mashiko, Yuji

en Mashiko, Yuji

Search repository
Tajima, Kazuyoshi

× Tajima, Kazuyoshi

en Tajima, Kazuyoshi

Search repository
Tokuda, Yoshiyuki

× Tokuda, Yoshiyuki

en Tokuda, Yoshiyuki

Search repository
Hirate, Yuichi

× Hirate, Yuichi

en Hirate, Yuichi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
言語 en
キーワード
主題Scheme Other
主題 felt strip
キーワード
主題Scheme Other
主題 aortic dissection
キーワード
主題Scheme Other
主題 hemolytic anemia
内容記述
内容記述タイプ Abstract
内容記述 Hemolytic anemia is a rare complication after aortic surgery. We herein report an early postoperative case of hemolytic anemia caused by an internal felt strip. A 57-year-old man underwent emergency partial aortic arch replacement for acute type A aortic dissection. The proximal stump was reinforced using internal and external polytetrafluoroethylene felt strips. The patient subsequently developed profound mechanical hemolytic anemia two weeks after the operation. Computed tomography did not reveal any narrowing of the anastomosis or kinking of the graft. However, transesophageal echocardiography confirmed that the internal felt strip had become inverted by the blood flow. Reoperation was performed to redo the proximal anastomosis, while also removing the internal felt strip. Hemolysis diminished soon after the reoperation. We encountered a case of acute aortic dissection that required reoperation because of hemolytic anemia caused by internal felt strip inversion. Further measures are required to prevent hemolysis with felt strips.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.87.3.590
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/873.html
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0027-7622
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 87, 号 3, p. 590-596, 発行日 2025-08
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-27 05:32:01.414186
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3