Neonatal nurses’ perceptions and objective indices of noise during quiet hours in the NICU

http://hdl.handle.net/2237/0002013522
http://hdl.handle.net/2237/0002013522
bdfdcb51-b44e-4ef6-ac0f-ff96d26c16bd
名前 / ファイル ライセンス アクション
neonatal_nurses__perceptions_and_objective_indices.8.pdf neonatal_nurses__perceptions_and_objective_indices.8.pdf (1000 KB)
アイテムタイプ itemtype_ver1(1)
公開日 2025-10-14
タイトル
タイトル Neonatal nurses’ perceptions and objective indices of noise during quiet hours in the NICU
言語 en
著者 Sugiura, Masato

× Sugiura, Masato

en Sugiura, Masato

Search repository
Shimizu, Jun

× Shimizu, Jun

en Shimizu, Jun

Search repository
Yano, Yoshiko

× Yano, Yoshiko

en Yano, Yoshiko

Search repository
Fujino, Masayuki

× Fujino, Masayuki

en Fujino, Masayuki

Search repository
Nakano, Takashi

× Nakano, Takashi

en Nakano, Takashi

Search repository
Miyata, Masafumi

× Miyata, Masafumi

en Miyata, Masafumi

Search repository
Niinomi, Kazuteru

× Niinomi, Kazuteru

en Niinomi, Kazuteru

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
言語 en
内容記述
内容記述タイプ Abstract
内容記述 Background: Noise adversely affects preterm infants in the neonatal intensive care unit (NICU), but past studies focused exclusively on quantifying its acoustic characteristics. Purpose: This study aims to examine the relationships between objective noise measurements and nurses’ subjective perceptions in the NICU and analyze how these measurements vary by location and time of day during quiet hours. Methods: In this observational study, noise was measured in 12 bays of an open-bay NICU during set times in the morning, afternoon, and evening. Subjective ratings of perceived noise were solicited from 25 nurses during these periods, converted to numerical scores, and ranked to categorize the bays into 3 measurement areas: loud, intermediate, and quiet. Noise indices were tested for associations with noise score, measurement area, and time by correlation and variance analyses. Results: The equivalent continuous sound level (Leq) ranged from 55 to 63 dB over 60-minute measurement periods. The L5 (level exceeded 5% of the 60-minute period) and the L50 (level exceeded 50% of the 60-minute period) were analyzed to capture short-duration high noise levels and typical ambient noise, respectively. Noise ratings showed weak correlations with Leq, L5, L50, and minimum sound levels (Lmin). Implications for Practice and Research: Strategies that consider location and time of day, with measures against sudden noise, are needed for NICU care. Future research should address comprehensive assessments of noise sources and their impact evaluation on preterm infants.
言語 en
出版者
出版者 Wolters Kluwer Health
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1097/ANC.0000000000001274
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 1536-0903
書誌情報 en : Advances in Neonatal Care

巻 25, 号 4, p. 353-362, 発行日 2025-08
戻る
0
views
See details
Views

Versions

Ver.1 2025-10-09 07:03:10.782117
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3