Partial Discharge Progress and Breakdown Characteristics of Oil-Impregnated Paper Insulation System for Capacitor Voltage Transformers

http://hdl.handle.net/2237/0002013564
http://hdl.handle.net/2237/0002013564
f095a471-a67d-4471-b07c-75fe27f3bdc5
名前 / ファイル ライセンス アクション
Partial_Discharge_Progress_and_Breakdown_Characteristics_of_Oil-impregnated_Paper_Insulation_System.pdf Partial_Discharge_Progress_and_Breakdown_Characteristics_of_Oil-impregnated_Paper_Insulation_System.pdf (2.1 MB)
アイテムタイプ itemtype_ver1(1)
公開日 2025-10-31
タイトル
タイトル Partial Discharge Progress and Breakdown Characteristics of Oil-Impregnated Paper Insulation System for Capacitor Voltage Transformers
言語 en
著者 Nagaki, Yuya

× Nagaki, Yuya

en Nagaki, Yuya

Search repository
Hayashi, Kyohei

× Hayashi, Kyohei

en Hayashi, Kyohei

Search repository
Kojima, Hiroki

× Kojima, Hiroki

en Kojima, Hiroki

Search repository
Yoshida, Masanobu

× Yoshida, Masanobu

en Yoshida, Masanobu

Search repository
Hayakawa, Naoki

× Hayakawa, Naoki

en Hayakawa, Naoki

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報 “© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.”
言語 en
内容記述
内容記述タイプ Abstract
内容記述 Capacitor voltage transformers (CVTs) with aluminum foil/oil-impregnated papers composite insulation system have been operated over 30 years in substations. An insulation diagnosis of CVT is expected to be based on detecting partial discharge (PD). However, PD characteristics from PD inception to breakdown (BD) have not been clarified yet. In an insulation diagnosis of CVT, it is necessary to diagnose a risk level of BD based on PD characteristics. In this article, we investigated the PD characteristics using electrical and optical measurement on the fundamental insulation model of CVT and discussed the PD progress characteristics leading to BD. Experimental results revealed that PD, which was generated from the aluminum foil electrode periphery, progressed from the creeping direction to the penetrating direction of the oil-impregnated papers, and then, BD occurred. When PD penetrated the oil-impregnated paper, PD charge increased, and hydrogen-based gas was generated. This PD progress can be an important factor to establish insulation diagnosis based on PD measurement of CVT.
言語 en
出版者
出版者 IEEE
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/TDEI.2024.3501994
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 1070-9878
書誌情報 en : IEEE Transactions on Dielectrics and Electrical Insulation

巻 32, 号 4, p. 2257-2264, 発行日 2025-08
戻る
0
views
See details
Views

Versions

Ver.1 2025-10-31 06:08:24.611773
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3