| アイテムタイプ |
itemtype_ver1(1) |
| 公開日 |
2025-12-01 |
| タイトル |
|
|
タイトル |
A novel method for measuring the backscatter factor on a curved surface for diagnostic X-rays using a flexible scintillator sheet |
|
言語 |
en |
| 著者 |
Nakanishi, Kohei
Yamamoto, Seiichi
Yoshida, Masato
Miwa, Kenta
Nishii, Ryuichi
|
| アクセス権 |
|
|
アクセス権 |
embargoed access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_f1cf |
| 権利 |
|
|
権利情報 |
This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s13246-025-01624-z |
|
言語 |
en |
| 内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
The ESD is calculated using the backscatter factor (BSF). However, BSFs for flat surfaces have been used even though simulations have shown that the BSFs for curved surfaces, which represent the human body more accurately, do not match those for flat surfaces. Measuring these values in practice presents a challenge because conventional dosimeters used for BSF measurement have sensitive volumes that cannot conform to curved surfaces. In this study, we measured the BSF for a curved surface using a flexible scintillator. The scintillator, composed of Gd₃Al₂Ga₃O₁₂ (GAGG) scintillator powder mixed with a silicone adhesive, was securely attached to the curved surface of a cylindrical phantom. Diagnostic X-rays were irradiated onto the scintillator, and the BSFs were evaluated as the ratio of the light output with and without the phantom. We successfully measured BSFs on a curved surface using a flexible scintillator. The mean difference between the BSFs obtained from the experiments using the flexible scintillator and those obtained from the simulations for the cylindrical phantom was 0.43%. The maximum difference was 1.47%, which was observed at a tube voltage of 40 kV. Thus, the BSFs measured using the flexible scintillator agree well with the simulated results. Our scintillator is useful for measuring BSFs on curved surfaces and contributes to dose management. |
|
言語 |
en |
| 内容記述 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Version of record (Online Published): 11 August 2025 |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
Springer |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプresource |
http://purl.org/coar/resource_type/c_6501 |
|
タイプ |
journal article |
| 出版タイプ |
|
|
出版タイプ |
AM |
|
出版タイプResource |
http://purl.org/coar/version/c_ab4af688f83e57aa |
| 関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.1007/s13246-025-01624-z |
| 収録物識別子 |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
2662-4729 |
| 書誌情報 |
en : Physical and Engineering Sciences in Medicine
発行日 2025-08-11
|
| ファイル公開日 |
|
|
日付 |
2026-08-11 |
|
日付タイプ |
Available |