Recurrent allergic reactions to unrecognized chlorhexidine exposure leading to pulseless electrical activity: a case report

https://doi.org/10.18999/nagjms.88.1.149
https://doi.org/10.18999/nagjms.88.1.149
7adadab1-c509-4b3c-9623-6db4bc0615aa
名前 / ファイル ライセンス アクション
13_Kawaguchi.pdf 13_Kawaguchi.pdf (723.5 KB)
license.icon
アイテムタイプ itemtype_ver1(1)
公開日 2026-02-27
タイトル
タイトル Recurrent allergic reactions to unrecognized chlorhexidine exposure leading to pulseless electrical activity: a case report
言語 en
著者 Kawaguchi, Akari

× Kawaguchi, Akari

en Kawaguchi, Akari

Search repository
Amano, Yasuhiro

× Amano, Yasuhiro

en Amano, Yasuhiro

Search repository
Ando, Takahiro

× Ando, Takahiro

en Ando, Takahiro

Search repository
Fujii, Tasuku

× Fujii, Tasuku

en Fujii, Tasuku

Search repository
Tamura, Takahiro

× Tamura, Takahiro

en Tamura, Takahiro

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
言語 en
キーワード
主題Scheme Other
主題 anaphylaxis
キーワード
主題Scheme Other
主題 chlorhexidine
キーワード
主題Scheme Other
主題 alcohol allergy
キーワード
主題Scheme Other
主題 catheter insertion
キーワード
主題Scheme Other
主題 pulseless electrical activity
内容記述
内容記述タイプ Abstract
内容記述 Chlorhexidine applied to the skin during catheter insertion can cause allergic reactions; however, its potential to cause perioperative anaphylaxis is often overlooked. Herein, we report a case of recurrent allergic reactions to unrecognized chlorhexidine exposure, leading to pulseless electrical activity. A 66-year-old man exhibited an allergic reaction during anesthesia induction for Y-graft replacement for an abdominal aortic aneurysm, and the planned surgery was aborted. Skin tests for anesthetics were negative. Two months later, he experienced itching after epidural catheter insertion but did not report it. During a second anesthesia induction, the patient experienced another allergic reaction of unknown etiology. Although hemodynamics stabilized after vasopressor administration, insertion of a central venous catheter 1 hour later to prevent further hypotension triggered pulseless electrical activity. Chlorhexidine was used as a skin disinfectant during catheter insertion before all four reactions and was confirmed to have caused the anaphylaxes using diagnostic tests. Chlorhexidine should be considered a potential cause of perioperative anaphylaxis.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.88.1.149
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/874.html
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0027-7622
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 88, 号 1, p. 149-156, 発行日 2026-02
戻る
0
views
See details
Views

Versions

Ver.1 2026-02-27 00:54:02.123113
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3