{"created":"2021-03-01T06:29:51.983423+00:00","id":22133,"links":{},"metadata":{"_buckets":{"deposit":"f60c14ca-2cde-486c-af39-773d09b5c544"},"_deposit":{"id":"22133","owners":[],"pid":{"revision_id":0,"type":"depid","value":"22133"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00022133","sets":["499:508:509:1866"]},"author_link":["65642","65643","65644","65645","65646","65647"],"control_number":"22133","item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"181","bibliographicPageStart":"175","bibliographicVolumeNumber":"78","bibliographic_titles":[{"bibliographic_title":"Nagoya Journal of Medical Science","bibliographic_titleLang":"en"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to investigate the feasibility of contrast-enhanced magnetic resonance (MR) pancreatography with intravenously administered gadolinium-based contrast material (GBCM) in healthy subjects. Eight healthy male subjects (age: 29–53 years old, median: 37 years old) were enrolled. Contrast-enhanced MR pancreatography was scanned with heavily T2-weighted three-dimensional fluid-attenuated inversion recovery (hT2W-3D-FLAIR) before and after intravenous GBCM administration. Two radiologists evaluated the images, referring to three-dimensional MR pancreatography by consensus. Scanning was performed five times at 1.5-h intervals (at 0.5, 2, 3.5, 5, and 6.5 h) after GBCM administration. In all subjects, pre-contrast-enhanced hT2W-3D-FLAIR images demonstrated no visualization of the main pancreatic duct. After GBCM administration, the main pancreatic duct was visualized in all subjects at 0.5 h (n=4, 50%) and/or 2 h (n=7, 88%). The mean signal intensity of the main pancreatic duct was 3.17 ± 0.78 at pre-contrast enhancement, 7.96 ± 4.60 at 0.5 h, and 8.08 ± 4.64 at 2 h. The signal intensity ratio of the main pancreatic duct against the pancreatic parenchyma was statistically higher (P < 0.01) at the 0.5-h and 2-h scans than that of pre-contrast-enhanced scan. Intravenously administered GBCM seeped into the pancreatic duct in sufficient concentration to alter the appearance of the main pancreatic duct by hT2W-3D-FLAIR in healthy subjects.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_9_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/24195"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18999/nagjms.78.2.175","subitem_identifier_reg_type":"JaLC"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Nagoya University Graduate School of Medicine, School of Medicine","subitem_publisher_language":"en"}]},"item_9_relation_43":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/782.html","subitem_relation_type_select":"URI"}}]},"item_9_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International","subitem_rights_language":"en","subitem_rights_resource":"http://creativecommons.org/licenses/by-nc-nd/4.0/"}]},"item_9_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_9_source_id_61":{"attribute_name":"ISSN(Online)","attribute_value_mlt":[{"subitem_source_identifier":"2186-3326","subitem_source_identifier_type":"EISSN"}]},"item_9_source_id_7":{"attribute_name":"ISSN(print)","attribute_value_mlt":[{"subitem_source_identifier":"0027-7622","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Suzuki, Kojiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65642","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Naganawa, Shinji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65643","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furuhashi, Naohiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65644","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamazaki, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65645","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ogawa, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65646","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawai, Hisashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65647","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"15_Suzuki.pdf","filesize":[{"value":"312.1 kB"}],"format":"application/pdf","licensetype":"license_5","mimetype":"application/pdf","url":{"label":"15_Suzuki.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/22133/files/15_Suzuki.pdf"},"version_id":"15d431e3-6eab-4827-adb7-fd79bddd1e70"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"pancreas","subitem_subject_scheme":"Other"},{"subitem_subject":"pancreatography","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic resonance imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"contrast material","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Contrast-enhanced magnetic resonance pancreatography with gadoteridol by heavily T2-weighted three-dimensional fluid-attenuated inversion recovery: preliminary results in healthy subjects","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Contrast-enhanced magnetic resonance pancreatography with gadoteridol by heavily T2-weighted three-dimensional fluid-attenuated inversion recovery: preliminary results in healthy subjects","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["1866"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-05-23"},"publish_date":"2016-05-23","publish_status":"0","recid":"22133","relation_version_is_last":true,"title":["Contrast-enhanced magnetic resonance pancreatography with gadoteridol by heavily T2-weighted three-dimensional fluid-attenuated inversion recovery: preliminary results in healthy subjects"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-11-17T01:38:46.656608+00:00"}