{"created":"2021-03-01T06:29:52.975654+00:00","id":22148,"links":{},"metadata":{"_buckets":{"deposit":"721b96d5-3e14-480f-ba4d-33beb36e660d"},"_deposit":{"id":"22148","owners":[],"pid":{"revision_id":0,"type":"depid","value":"22148"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00022148","sets":["320:321:322"]},"author_link":["65710","65711","65712","65713","65714","65715"],"item_10_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Effect of Sprinkler on Evacuation Dynamics in Compartment Fire","subitem_alternative_title_language":"en"}]},"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"28","bibliographicPageStart":"21","bibliographicVolumeNumber":"64","bibliographic_titles":[{"bibliographic_title":"日本火災学会論文集","bibliographic_titleLang":"ja"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"火災に備えてホテルなどの部屋には初期消火用のスプリンクラーが設置されているが,実際の火災を想定したデモ実験は難しく,避難行動の観点からスプリンクラーの有効性を明らかにするには数値シミュレーションが有効である。そこで本研究では,まず火災シミュレーションソフトFire Dynamics Simulator により部屋内の火災を模擬し,スプリンクラーの配置や散水量を変えて区画火災の数値シミュレーションを行った。FDSにより再現された火災の時系列データを用いて火災発生後の避難行動の数値シミュレーションを行った。煙の流動や延焼領域の拡大の違いからスプリンクラーが避難行動に及ぼす影響を避難時間および避難者が一酸化炭素に曝された時間により定量的に評価した。 ","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"Since fire is one of the most serious disasters, we need to reduce the potential of damages such as injury and burn, which is mainly caused by high heat fluxes from the burning area with strong luminous flames, accidental explosions, and toxic species of CO and smoke. In order to mitigate these losses, it is important to consider the appropriate room design with exits in the building for setting the safe evacuation route, coupled with effective instruments of fire extinguishers and alarms. For example, a sprinkler is an instrument used to put out a small fire. According to the legislative requirement, a fire sprinkler system is needed in shared accommodation buildings such as hotels. In planning individual actions for safety and in evaluating the effective instruments, it is necessary to understand the phenomena in fire and construct the fire evacuation plan in advance. For this purpose, the establishment of appropriate safety guidelines is essential, and the prediction of evacuees' behaviors in case of fire is important. However, it may be impractical to demonstrate the real fire, because the experiments are expectedly huge and dangerous. To assess the sprinkler during evacuation dynamics, it could be fruitful to conduct a numerical simulation. In this study, we simulated the compartment fire by FDS (Fire Dynamics Simulator). We changed the amount of water and the placement of the sprinklers. Based on data of fire dynamics by FDS simulations, we carried out the evacuation simulation. We examined the effect of sprinklers on the evacuation dynamics in terms of the fire spread and the smoke flow. Then, we discussed the evacuation time and CO exposure time during fire evacuation.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://doi.org/10.11196/kasai.64.3_21"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/24209"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本火災学会","subitem_publisher_language":"ja"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.11196/kasai.64.3_21","subitem_relation_type_select":"DOI"}}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0546-0794","subitem_source_identifier_type":"PISSN"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"竹内, 裕貴","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"65710","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 和弘","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"65711","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦, 慎之助","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"65712","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"TAKEUCHI, Yuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65713","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"YAMAMOTO, Kazuhiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65714","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"NISHIKI, Shinnosuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"65715","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-21"}],"displaytype":"detail","filename":"125_2.pdf","filesize":[{"value":"510.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"125_2.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/22148/files/125_2.pdf"},"version_id":"55f0fcdb-7c5a-4721-9c0c-1619879ec534"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Evacuation","subitem_subject_scheme":"Other"},{"subitem_subject":"Sprinkler","subitem_subject_scheme":"Other"},{"subitem_subject":"Compartment Fire","subitem_subject_scheme":"Other"},{"subitem_subject":"Numerical Simulation","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"区画火災の避難行動に及ぼすスプリンクラーの影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"区画火災の避難行動に及ぼすスプリンクラーの影響","subitem_title_language":"ja"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-05-25"},"publish_date":"2016-05-25","publish_status":"0","recid":"22148","relation_version_is_last":true,"title":["区画火災の避難行動に及ぼすスプリンクラーの影響"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:09:23.442917+00:00"}