{"created":"2021-03-01T06:30:32.702636+00:00","id":22753,"links":{},"metadata":{"_buckets":{"deposit":"f38da41b-fd0c-4672-9b3e-37c61c2498f9"},"_deposit":{"id":"22753","owners":[],"pid":{"revision_id":0,"type":"depid","value":"22753"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00022753","sets":["320:321:322"]},"author_link":["66971","66972","66973","66974","66975","66976"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"7700604","bibliographicPageStart":"7700604","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Electrical insulation of liquid nitrogen (LN2) for a high-temperature superconducting (HTS) power apparatus can be categorized into two breakdown (BD) modes. One is the intrinsic or conventional BD of LN2. The other is the BD of LN2 with transient bubbles, such as a quench. In this paper, the BD characteristics of LN2 with transient bubbles were investigated for different LN2 pressures and electrode diameters. Experimental results revealed that the BD strength of LN2 with transient bubbles was lower than the intrinsic BD strength of LN2. The difference between the intrinsic BD strength and the BD strength with transient bubbles in LN2 became smaller with the increase in the LN2 pressure and electrode diameter. Furthermore, the BD characteristics of LN2 with continuous bubbles were investigated and compared with the BD characteristics of LN2 with transient bubbles. As a result, the insulation design of an HTS power apparatus in consideration of their quench condition will be rationalized than the design based on the continuous thermal stress.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"http://doi.org/10.1109/TASC.2016.2532469"},{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/24909"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TASC.2016.2532469","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"“© © 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.”","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, N.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"66971","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsuoka, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"66972","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishida, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"66973","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kojima, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"66974","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Isojima, S.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"66975","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kuwata, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"66976","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-22"}],"displaytype":"detail","filename":"IEEE-TASC-2016.pdf","filesize":[{"value":"640.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"IEEE-TASC-2016.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/22753/files/IEEE-TASC-2016.pdf"},"version_id":"36954979-cac9-4e19-9320-b95ba2a48b06"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"electrical insulation","subitem_subject_scheme":"Other"},{"subitem_subject":"breakdown","subitem_subject_scheme":"Other"},{"subitem_subject":"liquid nitrogen","subitem_subject_scheme":"Other"},{"subitem_subject":"quench","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Pressure Dependence and Size Effect of LN2 Breakdown Characteristics Under Transient Thermal Stress","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Pressure Dependence and Size Effect of LN2 Breakdown Characteristics Under Transient Thermal Stress","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-09-28"},"publish_date":"2016-09-28","publish_status":"0","recid":"22753","relation_version_is_last":true,"title":["Pressure Dependence and Size Effect of LN2 Breakdown Characteristics Under Transient Thermal Stress"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:12:02.857018+00:00"}