{"_buckets": {"deposit": "c5313ba9-94d6-4a97-9ce0-4fac348f0234"}, "_deposit": {"id": "23540", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "23540"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00023540", "sets": ["322"]}, "author_link": ["69919", "69920", "69921", "69922", "69923", "69924"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-11-14", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "3230", "bibliographicPageStart": "3224", "bibliographicVolumeNumber": "23", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Dielectrics and Electrical Insulation", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Spark conditioning is an effective method for improving dielectric strength in vacuum. In this paper, we discuss the dependence of spark conditioning on breakdown (BD) charge and electrode material in vacuum under various non-uniform electric field and circuit parameters. We applied a negative impulse voltage to a rod-plane electrode configuration with a cathode made of stainless steel (SS), Cu-Cr, or OFHC Cu (Cu), and an anode made of SS or Cu. We changed the gap distance, the tip radius of the rod electrode and the circuit parameters. As a result, the conditioning effect, i.e. improving BD electric field strength by the conditioning, depended on the BD charge (QBD) and reached its maximum value against QBD. The optimal QBD required to achieve the maximum conditioning effect decreased with the cathode melting point. Moreover, when BD caused by cathode heating (CH-BD) occurred readily, with the SS anode, the BD electric field strength at the cathode surface after conditioning depended on QBD, regardless of the gap distance and the tip radius. Thus, for CH-BD, we estimated the withstand voltage that could be achieved by spark conditioning from the electrode configuration and QBD. However, when BD caused by anode heating (AH-BD) occurred easily with the Cu anode, the optimal QBD was larger than that for CH-BD because the cathode temperature was lower for AH-BD than for CH-BD.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "http://doi.org/10.1109/TDEI.2016.7736889"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/25737"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/TDEI.2016.7736889", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "“© 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.”", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1070-9878", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kojima, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "69919", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "69920", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayakawa, N.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "69921", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "69922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saito, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "69923", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakaki, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "69924", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "5989_rev3.pdf", "filesize": [{"value": "719.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 719500.0, "url": {"label": "5989_rev3.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/23540/files/5989_rev3.pdf"}, "version_id": "910e6273-dfef-495d-aaa0-1eec32149d72"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Vacuum discharge", "subitem_subject_scheme": "Other"}, {"subitem_subject": "conditioning", "subitem_subject_scheme": "Other"}, {"subitem_subject": "non-uniform electric field", "subitem_subject_scheme": "Other"}, {"subitem_subject": "vacuum circuit breakers", "subitem_subject_scheme": "Other"}, {"subitem_subject": "breakdown", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Dependence of Spark Conditioning on Breakdown Charge and Electrode Material under a Non-Uniform Electric Field in Vacuum", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dependence of Spark Conditioning on Breakdown Charge and Electrode Material under a Non-Uniform Electric Field in Vacuum", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/25737", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2017-03-21"}, "publish_date": "2017-03-21", "publish_status": "0", "recid": "23540", "relation": {}, "relation_version_is_last": true, "title": ["Dependence of Spark Conditioning on Breakdown Charge and Electrode Material under a Non-Uniform Electric Field in Vacuum"], "weko_shared_id": -1}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

Dependence of Spark Conditioning on Breakdown Charge and Electrode Material under a Non-Uniform Electric Field in Vacuum

http://hdl.handle.net/2237/25737
http://hdl.handle.net/2237/25737
c0378013-c5b8-4b86-a3ca-297b2480baef
名前 / ファイル ライセンス アクション
5989_rev3.pdf 5989_rev3.pdf (719.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-03-21
タイトル
タイトル Dependence of Spark Conditioning on Breakdown Charge and Electrode Material under a Non-Uniform Electric Field in Vacuum
言語 en
著者 Kojima, H.

× Kojima, H.

WEKO 69919

en Kojima, H.

Search repository
Takahashi, T.

× Takahashi, T.

WEKO 69920

en Takahashi, T.

Search repository
Hayakawa, N.

× Hayakawa, N.

WEKO 69921

en Hayakawa, N.

Search repository
Hasegawa, K.

× Hasegawa, K.

WEKO 69922

en Hasegawa, K.

Search repository
Saito, H.

× Saito, H.

WEKO 69923

en Saito, H.

Search repository
Sakaki, M.

× Sakaki, M.

WEKO 69924

en Sakaki, M.

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 “© 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.”
キーワード
主題Scheme Other
主題 Vacuum discharge
キーワード
主題Scheme Other
主題 conditioning
キーワード
主題Scheme Other
主題 non-uniform electric field
キーワード
主題Scheme Other
主題 vacuum circuit breakers
キーワード
主題Scheme Other
主題 breakdown
抄録
内容記述 Spark conditioning is an effective method for improving dielectric strength in vacuum. In this paper, we discuss the dependence of spark conditioning on breakdown (BD) charge and electrode material in vacuum under various non-uniform electric field and circuit parameters. We applied a negative impulse voltage to a rod-plane electrode configuration with a cathode made of stainless steel (SS), Cu-Cr, or OFHC Cu (Cu), and an anode made of SS or Cu. We changed the gap distance, the tip radius of the rod electrode and the circuit parameters. As a result, the conditioning effect, i.e. improving BD electric field strength by the conditioning, depended on the BD charge (QBD) and reached its maximum value against QBD. The optimal QBD required to achieve the maximum conditioning effect decreased with the cathode melting point. Moreover, when BD caused by cathode heating (CH-BD) occurred readily, with the SS anode, the BD electric field strength at the cathode surface after conditioning depended on QBD, regardless of the gap distance and the tip radius. Thus, for CH-BD, we estimated the withstand voltage that could be achieved by spark conditioning from the electrode configuration and QBD. However, when BD caused by anode heating (AH-BD) occurred easily with the Cu anode, the optimal QBD was larger than that for CH-BD because the cathode temperature was lower for AH-BD than for CH-BD.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 IEEE
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/TDEI.2016.7736889
ISSN
収録物識別子タイプ PISSN
収録物識別子 1070-9878
書誌情報 en : IEEE Transactions on Dielectrics and Electrical Insulation

巻 23, 号 5, p. 3224-3230, 発行日 2016-11-14
著者版フラグ
値 author
URI
識別子 http://doi.org/10.1109/TDEI.2016.7736889
識別子タイプ DOI
URI
識別子 http://hdl.handle.net/2237/25737
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 14:31:37.552931
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3