@article{oai:nagoya.repo.nii.ac.jp:00023729, author = {安藤, 聡一郎 and 北根, 安雄 and 西島, 悠太 and 伊藤, 義人 and 中野, 裕二郎 and Ando, Soichiro and Kitane, Yasuo and Nishijima, Yuta and Itoh, Yoshito and Nakano, Yujiro}, journal = {構造工学論文集A}, month = {Mar}, note = {Thickness measurement is essential to precise condition assessment of steel structures. In this research, the pulsed eddy current (PEC) thickness measurement method is studied, which can measure thickness without the surface treatment. The applicable limit of PEC is examined by measuring the thickness of specimens with various types of thickness loss and performing a finite element method for thickness-reduced steel plates of different types. As a result, it is found that to measure the reduced thickness of a small pitting is difficult, but to measure the average thickness is possible when thickness reduction is spread in a wider area. In addition, a measuring range of PEC and the effect of specimen's shape on measured thickness values are identified.}, pages = {603--616}, title = {種々の断面欠損鋼板に対するパルス渦電流板厚測定法で得られる検出信号の特徴に関する研究}, volume = {62}, year = {2016} }