WEKO3
アイテム
The changes of aortic diameter after aortic repair with aortic tailoring technique for chronic type B aortic dissection
http://hdl.handle.net/2237/26501
http://hdl.handle.net/2237/2650135b9c49c-17ce-4ca1-b505-65cc894f2e48
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-05-24 | |||||
タイトル | ||||||
タイトル | The changes of aortic diameter after aortic repair with aortic tailoring technique for chronic type B aortic dissection | |||||
言語 | en | |||||
著者 |
Suenaga, Hiroto
× Suenaga, Hiroto× Usui, Akihiko× Mutsuga, Masato× Oshima, Hideki× Abe, Tomonobu× Narita, Yuji× Fujimoto, Kazuro× Tokuda, Yoshiyuki |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | This is a pre-copyedited, author-produced version of an article accepted for publication in [European Journal of Cardio-Thoracic Surgery] following peer review. The version of record [European Journal of Cardio-Thoracic Surgery. v.50, n.6, 2016, p.1118-1123 ] is available online at: https://doi.org/10.1093/ejcts/ezw240 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Aortic tailoring | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Chronic type B aortic dissection | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Paraplegia | |||||
抄録 | ||||||
内容記述 | OBJECTIVES: Aortic repair with aortic tailoring of the false lumen can preserve the true lumen and intercostal arteries naturally. It is a useful surgical strategy to prevent paraplegia. However, aortic remodelling of tailored segments in a late phase after surgery is another concern. This study investigates the destiny of aortic remodelling of tailored aorta. METHODS: From June 2004 to April 2013, 21 consecutive patients underwent aortic tailoring operation for chronic type B aortic dissecting aneurysm. The mean age at operation was 60 ± 10 years (range, 43–77). The tailored aortic segments were followed by serial CT scanning with the mean follow-up period of 46 ± 32 months (range, 2–103). RESULTS: There were no operative deaths but paraplegia in 1, stroke in 1 and reversible renal failure in 2 patients. There were two late deaths: one due to pneumonia and the other due to aneurysmal rupture of the abdominal aorta. Eighteen patients revealed a completely thrombosed false lumen and no expansion of the tailored aorta, with it remaining less than 40 mm in diameter during follow-up. However, 3 cases were associated with a patent false lumen and 2 cases revealed aortic events. The aortic event-free rate at 5 years was 95 ± 5.1% in all patients and 66 ± 27% in patients in the patent false lumen group. CONCLUSIONS: Aortic tailoring is a useful surgical technique for chronic type B aortic dissection. Paraplegia and ischaemia of other visceral organs could less likely occur. Patients with a completely thrombosed false lumen revealed no aortic events; however, a patent false lumen was associated with a high risk of aortic events. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | Oxford University Press | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1093/ejcts/ezw240 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1010-7940 | |||||
書誌情報 |
en : European Journal of Cardio-Thoracic Surgery 巻 50, 号 6, p. 1118-1123, 発行日 2016-12 |
|||||
著者版フラグ | ||||||
値 | author | |||||
URI | ||||||
識別子 | https://doi.org/10.1093/ejcts/ezw240 | |||||
識別子タイプ | DOI | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/26501 | |||||
識別子タイプ | HDL |