WEKO3
アイテム
{"_buckets": {"deposit": "3b795142-96fa-4670-bdcf-9ccb1a069f7a"}, "_deposit": {"id": "25706", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "25706"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00025706", "sets": ["322"]}, "author_link": ["76136", "76137", "76138", "76139", "76140"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-11-27", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "3269", "bibliographicPageStart": "3265", "bibliographicVolumeNumber": "24", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Dielectrics and Electrical Insulation", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Vacuum interrupter has a composite insulation system. When an internal insulation fails, the discharge has complex and various patterns. Previously, based on the discharge development characteristics, we proposed a discrimination method for the discharge pattern in vacuum interrupter. We measured the applied voltage, anode current, and shield potential waveforms, respectively. From the analysis of the measured waveforms, we can estimate the discharge patterns and discharge path lengths. In this paper, a non-contact shield potential measurement was proposed when the shield potential cannot be measured directly. Furthermore, verification tests with this measurement method were conducted and the effectiveness of the discrimination method was confirmed.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/TDEI.2017.006512", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "“© 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.” ", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1070-9878", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kong, Fei", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "76136", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kojima, Hiroki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "76137", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayakawa, Naoki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "76138", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kimura, Toshinori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "76139", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsukima, Mitsuru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "76140", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-04-17"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "6512-revised-hayakawa2.pdf", "filesize": [{"value": "975.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 975000.0, "url": {"label": "6512-revised-hayakawa2", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/25706/files/6512-revised-hayakawa2.pdf"}, "version_id": "a6d5822d-8b27-4f28-90b7-e7656352c2e4"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Vacuum interrupter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "floating electrode", "subitem_subject_scheme": "Other"}, {"subitem_subject": "discharge diagnostics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "breakdown", "subitem_subject_scheme": "Other"}, {"subitem_subject": "surface flashover", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Discharge pattern discrimination in vacuum interrupter with non-contact measurement of shield potential", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Discharge pattern discrimination in vacuum interrupter with non-contact measurement of shield potential", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/00027914", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2018-04-17"}, "publish_date": "2018-04-17", "publish_status": "0", "recid": "25706", "relation": {}, "relation_version_is_last": true, "title": ["Discharge pattern discrimination in vacuum interrupter with non-contact measurement of shield potential"], "weko_shared_id": -1}
Discharge pattern discrimination in vacuum interrupter with non-contact measurement of shield potential
http://hdl.handle.net/2237/00027914
http://hdl.handle.net/2237/00027914f1c41caa-aa3d-42ef-be2b-3cd109ae01d0
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-04-17 | |||||
タイトル | ||||||
タイトル | Discharge pattern discrimination in vacuum interrupter with non-contact measurement of shield potential | |||||
言語 | en | |||||
著者 |
Kong, Fei
× Kong, Fei× Kojima, Hiroki× Hayakawa, Naoki× Kimura, Toshinori× Tsukima, Mitsuru |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | “© 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.” | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Vacuum interrupter | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | floating electrode | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | discharge diagnostics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | breakdown | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | surface flashover | |||||
抄録 | ||||||
内容記述 | Vacuum interrupter has a composite insulation system. When an internal insulation fails, the discharge has complex and various patterns. Previously, based on the discharge development characteristics, we proposed a discrimination method for the discharge pattern in vacuum interrupter. We measured the applied voltage, anode current, and shield potential waveforms, respectively. From the analysis of the measured waveforms, we can estimate the discharge patterns and discharge path lengths. In this paper, a non-contact shield potential measurement was proposed when the shield potential cannot be measured directly. Furthermore, verification tests with this measurement method were conducted and the effectiveness of the discrimination method was confirmed. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | IEEE | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/TDEI.2017.006512 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1070-9878 | |||||
書誌情報 |
en : IEEE Transactions on Dielectrics and Electrical Insulation 巻 24, 号 5, p. 3265-3269, 発行日 2017-11-27 |
|||||
著者版フラグ | ||||||
値 | author |