WEKO3
アイテム
{"_buckets": {"deposit": "e400f01f-763a-4b61-8bf7-31257c741489"}, "_deposit": {"id": "28238", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "28238"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00028238", "sets": ["2418"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "215", "bibliographicPageStart": "207", "bibliographicVolumeNumber": "81", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Differences of the effect of annuloplasty rings on the mitral annulus and leaflets, and differences between types of annuloplasty rings are not well known. We analyzed annular motion and leaflet movement with a rigid or flexible ring and without a ring using an isolated swine working heart model. Hearts of 10 swine (weight: 40–50 kg) were used for a rigid ring (n=5) and a flexible ring (n=5). Four ultrasound crystal tips were fixed around the annulus and an annuloplasty ring was implanted in the isolated heart. In the working heart mode, measurement of mitral annular dimension was acquired by sonomicrometry. Images of mitral valve motion were acquired by a high-speed video camera. The same analyses were performed after removing the artificial ring. The antero-posterior diameter of the diastole distance was significantly reduced in the flexible ring (21.59±0.71 mm) and rigid ring (15.93±1.88 mm) compared with no ring (23.51±2.01 mm). The flexible ring made the transverse diameter shrink significantly more than did the rigid ring. The contraction range of the transverse diameter was significantly smaller in the flexible ring compared with no ring. The duration of opening to closing of the mitral leaflet with the rigid (124.7±4.4 ms) and flexible rings (107.9±3.5 ms) was significantly shorter than that with no ring (168±36.5 ms). Annuloplasty rings allow simplicity of leaflet motion, regardless of the type of artificial ring. In a flexible ring, the mitral annulus shows a vertically long shape, suggesting preservation of posterior annular movement.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.81.2.207", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine"}]}, "item_9_relation_43": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/812.html ", "subitem_relation_type_select": "URI"}}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yokote, Jun"}], "nameIdentifiers": [{"nameIdentifier": "92000", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Araki, Yoshimori"}], "nameIdentifiers": [{"nameIdentifier": "92001", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saito, Shunei"}], "nameIdentifiers": [{"nameIdentifier": "92002", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, Hiroki"}], "nameIdentifiers": [{"nameIdentifier": "92003", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Usui, Akihiko"}], "nameIdentifiers": [{"nameIdentifier": "92004", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-06-13"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "04_Yokote.pdf", "filesize": [{"value": "3.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3400000.0, "url": {"label": "04_Yokote.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/28238/files/04_Yokote.pdf"}, "version_id": "5ecd6e0c-70fc-4b5e-afe6-f639ca5e779b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "mitral valve", "subitem_subject_scheme": "Other"}, {"subitem_subject": "annuloplasty ring", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heart physiology", "subitem_subject_scheme": "Other"}, {"subitem_subject": "isolated heart model", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effect of an artificial ring on mitral valve function", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effect of an artificial ring on mitral valve function"}]}, "item_type_id": "9", "owner": "1", "path": ["2418"], "permalink_uri": "https://doi.org/10.18999/nagjms.81.2.207", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-06-13"}, "publish_date": "2019-06-13", "publish_status": "0", "recid": "28238", "relation": {}, "relation_version_is_last": true, "title": ["Effect of an artificial ring on mitral valve function"], "weko_shared_id": 3}
Effect of an artificial ring on mitral valve function
https://doi.org/10.18999/nagjms.81.2.207
https://doi.org/10.18999/nagjms.81.2.2078bd54f18-a29a-4800-9e8d-e01f0c266bca
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-06-13 | |||||
タイトル | ||||||
タイトル | Effect of an artificial ring on mitral valve function | |||||
著者 |
Yokote, Jun
× Yokote, Jun× Araki, Yoshimori× Saito, Shunei× Hasegawa, Hiroki× Usui, Akihiko |
|||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | mitral valve | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | annuloplasty ring | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | heart physiology | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | isolated heart model | |||||
抄録 | ||||||
内容記述 | Differences of the effect of annuloplasty rings on the mitral annulus and leaflets, and differences between types of annuloplasty rings are not well known. We analyzed annular motion and leaflet movement with a rigid or flexible ring and without a ring using an isolated swine working heart model. Hearts of 10 swine (weight: 40–50 kg) were used for a rigid ring (n=5) and a flexible ring (n=5). Four ultrasound crystal tips were fixed around the annulus and an annuloplasty ring was implanted in the isolated heart. In the working heart mode, measurement of mitral annular dimension was acquired by sonomicrometry. Images of mitral valve motion were acquired by a high-speed video camera. The same analyses were performed after removing the artificial ring. The antero-posterior diameter of the diastole distance was significantly reduced in the flexible ring (21.59±0.71 mm) and rigid ring (15.93±1.88 mm) compared with no ring (23.51±2.01 mm). The flexible ring made the transverse diameter shrink significantly more than did the rigid ring. The contraction range of the transverse diameter was significantly smaller in the flexible ring compared with no ring. The duration of opening to closing of the mitral leaflet with the rigid (124.7±4.4 ms) and flexible rings (107.9±3.5 ms) was significantly shorter than that with no ring (168±36.5 ms). Annuloplasty rings allow simplicity of leaflet motion, regardless of the type of artificial ring. In a flexible ring, the mitral annulus shows a vertically long shape, suggesting preservation of posterior annular movement. | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.81.2.207 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/812.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
Nagoya Journal of Medical Science 巻 81, 号 2, p. 207-215, 発行日 2019-05 |
|||||
著者版フラグ | ||||||
値 | publisher |