{"created":"2021-03-01T06:36:44.328157+00:00","id":28632,"links":{},"metadata":{"_buckets":{"deposit":"e9c6e25e-f0ce-4cb2-9ce6-fa37337b4be6"},"_deposit":{"id":"28632","owners":[],"pid":{"revision_id":0,"type":"depid","value":"28632"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00028632"},"item_10_biblio_info_6":{"attribute_name":"\u66f8\u8a8c\u60c5\u5831","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"447","bibliographicPageStart":"439","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"Digestive Endoscopy"}]}]},"item_10_description_4":{"attribute_name":"\u6284\u9332","attribute_value_mlt":[{"subitem_description":"Objectives: The time to recurrent biliary obstruction (TRBO) of unresectable distal malignant biliary obstruction is generally thought to be longer when a self\u2010expandable metal stent (SEMS) with a thicker inner diameter is used for drainage, but the dependence on the inner diameter using a fully covered SEMS (FCSEMS) is uncertain. The objective of this multicenter prospective study was to compare TRBO and adverse events, such as cholecystitis and pancreatitis, in treatment of patients with unresectable malignant biliary obstruction using 8\u2010 and 10\u2010mm diameter FCSEMS. Methods: Eighteen tertiary\u2010care centers participated in the study. Patients were allocated to the 8\u2010 and 10\u2010mm diameter groups. TRBO, non\u2010inferiority of the 8\u2010mm FCSEMS, overall survival time, frequency and type of adverse events, and non\u2010recurrent biliary obstruction (RBO) rate at the time of death were compared between the two groups. Results: Median TRBO did not differ significantly between the 8\u2010mm (n = 102) and 10\u2010mm (n = 100) groups (275 vs 293 days, P = 0.971). The hazard ratio of the 8\u2010 to 10\u2010mm groups was 0.90 (80% confidence interval, 0.77\u20131.04; upper limit lower than the acceptable hazard ratio [1.33] of the null hypothesis). Based on these findings, the 8\u2010mm diameter stent was determined to be non\u2010inferior to the 10\u2010mm diameter stent. Survival time, incidence of adverse events and non\u2010RBO rate at the time of death did not differ significantly between the two groups. Conclusions: Time to RBO with an 8\u2010mm diameter FCSEMS was non\u2010inferior to that with a 10\u2010mm diameter FCSEMS. This finding is important for development of future SEMS.","subitem_description_type":"Abstract"}]},"item_10_description_5":{"attribute_name":"\u5185\u5bb9\u8a18\u8ff0","attribute_value_mlt":[{"subitem_description":"\u30d5\u30a1\u30a4\u30eb\u516c\u958b\uff1a2020-07-01","subitem_description_type":"Other"}]},"item_10_publisher_32":{"attribute_name":"\u51fa\u7248\u8005","attribute_value_mlt":[{"subitem_publisher":"Wiley"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1111/den.13366","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"\u6a29\u5229","attribute_value_mlt":[{"subitem_rights":"\"This is the peer reviewed version of the following article: [Kawashima, H. , Hashimoto, S. , Ohno, E. , Ishikawa, T. , Morishima, T. , Matsubara, H. , Sugimoto, H. , Nonogaki, K. , Kanamori, A. , Hara, K. , Kuwahara, T. , Nakamura, M. , Miyahara, R. , Ishigami, M. , Ando, M. , Hirooka, Y. and , (2019), Comparison of 8\u2010 and 10\u2010mm diameter fully covered self\u2010expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction. Digestive Endoscopy, 31: 439-447. doi:10.1111/den.13366], which has been published in final form at [https://doi.org/10.1111/den.13366]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.\""}]},"item_10_select_15":{"attribute_name":"\u8457\u8005\u7248\u30d5\u30e9\u30b0","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_10_source_id_61":{"attribute_name":"ISSN\uff08print\uff09","attribute_value_mlt":[{"subitem_source_identifier":"0915-5635","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"\u8457\u8005","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kawashima, Hiroki"}],"nameIdentifiers":[{"nameIdentifier":"93810","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hashimoto, Senju"}],"nameIdentifiers":[{"nameIdentifier":"93811","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohno, Eizaburo"}],"nameIdentifiers":[{"nameIdentifier":"93812","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishikawa, Takuya"}],"nameIdentifiers":[{"nameIdentifier":"93813","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Morishima, Tomomasa"}],"nameIdentifiers":[{"nameIdentifier":"93814","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsubara, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"93815","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sugimoto, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"93816","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nonogaki, Koji"}],"nameIdentifiers":[{"nameIdentifier":"93817","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanamori, Akira"}],"nameIdentifiers":[{"nameIdentifier":"93818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hara, Kazuo"}],"nameIdentifiers":[{"nameIdentifier":"93819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kuwahara, Takamichi"}],"nameIdentifiers":[{"nameIdentifier":"93820","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakamura, Masanao"}],"nameIdentifiers":[{"nameIdentifier":"93821","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Miyahara, Ryoji"}],"nameIdentifiers":[{"nameIdentifier":"93822","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishigami, Masatoshi"}],"nameIdentifiers":[{"nameIdentifier":"93823","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ando, Masahiko"}],"nameIdentifiers":[{"nameIdentifier":"93824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirooka, Yoshiki"}],"nameIdentifiers":[{"nameIdentifier":"93825","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"\u30d5\u30a1\u30a4\u30eb\u60c5\u5831","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-07-01"}],"displaytype":"detail","filename":"JGES-DEN-2018-8274.pdf","filesize":[{"value":"354.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JGES-DEN-2018-8274","url":"https://nagoya.repo.nii.ac.jp/record/28632/files/JGES-DEN-2018-8274.pdf"},"version_id":"a1a08ecc-b5c7-4a34-8646-7675befed85e"}]},"item_keyword":{"attribute_name":"\u30ad\u30fc\u30ef\u30fc\u30c9","attribute_value_mlt":[{"subitem_subject":"drainage","subitem_subject_scheme":"Other"},{"subitem_subject":"endoscopic retrograde cholangiography","subitem_subject_scheme":"Other"},{"subitem_subject":"stents","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"\u8a00\u8a9e","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"\u8cc7\u6e90\u30bf\u30a4\u30d7","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Comparison of 8\u2010 and 10\u2010mm diameter fully covered self\u2010expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction","item_titles":{"attribute_name":"\u30bf\u30a4\u30c8\u30eb","attribute_value_mlt":[{"subitem_title":"Comparison of 8\u2010 and 10\u2010mm diameter fully covered self\u2010expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction"}]},"item_type_id":"10","owner":"1","path":["499/500/501"],"pubdate":{"attribute_name":"\u516c\u958b\u65e5","attribute_value":"2019-10-21"},"publish_date":"2019-10-21","publish_status":"0","recid":"28632","relation_version_is_last":true,"title":["Comparison of 8\u2010 and 10\u2010mm diameter fully covered self\u2010expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2021-03-01T09:56:06.278149+00:00"}