{"created":"2021-03-01T06:36:46.653591+00:00","id":28668,"links":{},"metadata":{"_buckets":{"deposit":"0cc7a282-3085-44fd-8464-6760cc7e867a"},"_deposit":{"id":"28668","owners":[],"pid":{"revision_id":0,"type":"depid","value":"28668"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00028668","sets":["673:674:675"]},"author_link":["94103","94104","94105"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageStart":"10E726","bibliographicVolumeNumber":"79","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, we investigate designs for polychromators of the ITER edge Thomson scattering system by means of numerical calculations. For this purpose, we discuss the optimum transmission wavelength ranges of the optical filters and the optimum number of filters. Five different filter arrangements, including those with an optical notch filter to eliminate Dα emission, are compared with each other. The measurement accuracy when using a polychromator is evaluated for midplane port configuration. It is found that the optimum filter number keeping in mind the cost performance cost is 5 or 6. Moreover, the use of an optical notch filter increases the measurement accuracy by approximately 5%.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.2969285","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 2008 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing.The following article appeared in (Review of Scientific Instruments. v.79, n.10, 2008, p.10E726) and may be found at (http://dx.doi.org/10.1063/1.2969285).","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_61":{"attribute_name":"ISSN(print)","attribute_value_mlt":[{"subitem_source_identifier":"0034-6748","subitem_source_identifier_type":"PISSN"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kajita, Shin","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"94103","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hatae, Takaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"94104","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kusama, Yoshinori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"94105","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-11-07"}],"displaytype":"detail","filename":"1_2969285.pdf","filesize":[{"value":"491.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1_2969285","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/28668/files/1_2969285.pdf"},"version_id":"5b0f5834-c8ac-485b-9ac8-c90857dd6459"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Design study of polychromators for ITER edge Thomson scattering diagnostics","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Design study of polychromators for ITER edge Thomson scattering diagnostics","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-11-07"},"publish_date":"2019-11-07","publish_status":"0","recid":"28668","relation_version_is_last":true,"title":["Design study of polychromators for ITER edge Thomson scattering diagnostics"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:21:12.672058+00:00"}