{"created":"2021-03-01T06:39:13.922435+00:00","id":30866,"links":{},"metadata":{"_buckets":{"deposit":"dd80e669-7c48-495e-9e27-dd94cc1617f5"},"_deposit":{"id":"30866","owners":[],"pid":{"revision_id":0,"type":"depid","value":"30866"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00030866","sets":["320:2524:2544:2585"]},"author_link":["102193"],"item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1982-03-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"128","bibliographicPageStart":"91","bibliographicVolumeNumber":"33","bibliographic_titles":[{"bibliographic_title":"Memoirs of the Faculty of Engineering, Nagoya University","bibliographic_titleLang":"en"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It is considered desirable that air-conditioning for large spaces should be restricted only to the space within the occupied zone from the viewpoint of economical feasibility and energy conservation. This is a report on the application of the occupied zone air-conditioning to three different large spaces : an exposition hall, a sport hall and a factory of large machine assembly at constant temperature. The distribution of air and temperature were first examined by the experiments with the scaled models followed by the actual measurements. The results obtained by the experiments have proved that the proposed similarity theory on space air distribution can be verified after comparing them with the predicted values. The heat load calculation method for the occupied zone air-conditioning is also proposed in this paper. In addition, the performance of the induction type of outlets suitable for large spaces are analyzed by experiments in detail.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18999/memfenu.33.2.91","subitem_identifier_reg_type":"JaLC"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Faculty of Engineering, Nagoya University","subitem_publisher_language":"en"}]},"item_9_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_9_source_id_7":{"attribute_name":"ISSN(print)","attribute_value_mlt":[{"subitem_source_identifier":"0027-7657","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakahara, Nobuo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"102193","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-24"}],"displaytype":"detail","filename":"33-2-01.pdf","filesize":[{"value":"4.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"33-2-01.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/30866/files/33-2-01.pdf"},"version_id":"47b81e82-08c8-46b9-981b-5450fddff4c4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["2585"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-11-24"},"publish_date":"2020-11-24","publish_status":"0","recid":"30866","relation_version_is_last":true,"title":["Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T04:40:45.105407+00:00"}