{"created":"2021-03-01T06:39:51.034606+00:00","id":31424,"links":{},"metadata":{"_buckets":{"deposit":"321c31c0-4322-4968-8b88-c360649ddbc5"},"_deposit":{"id":"31424","owners":[],"pid":{"revision_id":0,"type":"depid","value":"31424"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00031424","sets":["320:2524:2544:2633"]},"author_link":["103655","103656"],"item_1615768549627":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1958-09-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"70","bibliographicPageStart":"64","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"Memoirs of the Faculty of Engineering, Nagoya University","bibliographic_titleLang":"en"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper describes the results of a experiments made with the radio-frequency noise (0.1-30 MC) in the hot-cathode gas discharge tubes. These results show that the gas, gas pressure and discharge current have some considerable influence on the noise. In the tubes containing argon gas and mercury vapour two different types of noise appear depending on the condition of discharge, while the tubes filled only with argon gas have one type only. The distribution of noise along the tube axis suggests a possible origin and mechanism of noise generation.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_9_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18999/memfenu.10.1.64","subitem_identifier_reg_type":"JaLC"}]},"item_9_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Faculty of Engineering, Nagoya University","subitem_publisher_language":"en"}]},"item_9_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_9_source_id_7":{"attribute_name":"ISSN(print)","attribute_value_mlt":[{"subitem_source_identifier":"0027-7657","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Akao, Yasuo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"103655","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kobayashi, Senshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"103656","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-02-12"}],"displaytype":"detail","filename":"10-1-05.pdf","filesize":[{"value":"791.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"10-1-05.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/31424/files/10-1-05.pdf"},"version_id":"65667aa1-ad97-4639-bce1-ce0c101bf6fe"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Radio-Frequency noise in hot-cathode gas discharge tubes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Radio-Frequency noise in hot-cathode gas discharge tubes","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["2633"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-02-12"},"publish_date":"2021-02-12","publish_status":"0","recid":"31424","relation_version_is_last":true,"title":["Radio-Frequency noise in hot-cathode gas discharge tubes"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T05:12:40.805817+00:00"}