{"created":"2021-03-01T06:11:42.686858+00:00","id":5165,"links":{},"metadata":{"_buckets":{"deposit":"f3eead8a-3569-44ce-8b68-e6bb54f0e309"},"_deposit":{"id":"5165","owners":[],"pid":{"revision_id":0,"type":"depid","value":"5165"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00005165","sets":["320:321:322"]},"author_link":["12935","12936","12937"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"1939","bibliographicPageStart":"1936","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this paper, we propose a \"Superconducting Fault Current Limiting Transformer (SFCLT)\"; superconducting transformer equipped with the function of superconducting fault current limiter. We discussed the operating characteristics of SFCLT introduced into a simplified power transmission model system. Fault current, transient stability, overvoltage and thermal characteristics of SFCLT were analyzed in the model system. It was finally revealed that SFCLT could satisfactorily bring about the functions of fmlt current suppression and power system stability improvement.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/6749"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/77.920230","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2001 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, N.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kagawa, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12937","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"00920230.pdf","filesize":[{"value":"357.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"00920230.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/5165/files/00920230.pdf"},"version_id":"7cb417ef-672e-49cf-b822-8f135dbca92e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Superconducting fault current limiter","subitem_subject_scheme":"Other"},{"subitem_subject":"Superconducting transformer","subitem_subject_scheme":"Other"},{"subitem_subject":"Power transmission system","subitem_subject_scheme":"Other"},{"subitem_subject":"Power system stability","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A system study on superconducting fault current limiting transformer (SFCLT) with the functions of fault current suppression and system stability improvement","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A system study on superconducting fault current limiting transformer (SFCLT) with the functions of fault current suppression and system stability improvement","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2006-07-28"},"publish_date":"2006-07-28","publish_status":"0","recid":"5165","relation_version_is_last":true,"title":["A system study on superconducting fault current limiting transformer (SFCLT) with the functions of fault current suppression and system stability improvement"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:49:44.849010+00:00"}