{"created":"2021-03-01T06:11:45.000301+00:00","id":5199,"links":{},"metadata":{"_buckets":{"deposit":"c14e8ca5-28cc-4a9a-bf44-44afd96f3756"},"_deposit":{"id":"5199","owners":[],"pid":{"revision_id":0,"type":"depid","value":"5199"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00005199","sets":["320:321:322"]},"author_link":["13088","13089","13090"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"1959","bibliographicPageStart":"1956","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have proposed a “Flux-Lock” type high T, superconducting (HTS) fault current limiter (FCL) composed of the flux-lock reactor with HTS element and the magnetic field coil circuit, In this FCL, the initial limiting current level can be arranged by setting inductance combination of the flux-lock coils and an ac magnetic field is applied to the HTS to get higher resistance only in a current limiting phase. This paper describes design guidelines for the HTS-FCLs. The impedances of the FCLs were expressed as a function of the product of the normal resistance and the square of the quench current level, which we have proposed to refer to as ‘Lquench power”. Supposing the FCLs are introduced into the extra-high voltage transmission system and power distribution system, the “quench power” necessary for the FCLs to suppress the fault current under the required level was discussed.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/6783"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/77.920235","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2001 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Matsumura, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13088","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimizu, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13089","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yokomizu, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13090","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"00920235.pdf","filesize":[{"value":"397.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"00920235.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/5199/files/00920235.pdf"},"version_id":"96b6f08c-b7d8-4fce-a0c2-d66f709ab4f6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"fault current limiter","subitem_subject_scheme":"Other"},{"subitem_subject":"high Tc superconducting element","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic field","subitem_subject_scheme":"Other"},{"subitem_subject":"resistance","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Design guideline of flux-lock type HTS fault current limiter for power system application","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Design guideline of flux-lock type HTS fault current limiter for power system application","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2006-08-02"},"publish_date":"2006-08-02","publish_status":"0","recid":"5199","relation_version_is_last":true,"title":["Design guideline of flux-lock type HTS fault current limiter for power system application"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:49:50.662170+00:00"}