{"created":"2021-03-01T06:11:46.346662+00:00","id":5220,"links":{},"metadata":{"_buckets":{"deposit":"d182191c-7bfa-40cf-92d9-21305f7f19f0"},"_deposit":{"id":"5220","owners":[],"pid":{"revision_id":0,"type":"depid","value":"5220"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00005220","sets":["320:321:322"]},"author_link":["13177","13178","13179","13180","13181","13182","13183","13184"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"1036","bibliographicPageStart":"1033","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a “Prospective Power Transmission Model System Integrated under Superconducting Environment”, abbreviated to PROMISE, with the transmission capability of 6kV-1000kVA. The PROMISE consists of a superconducting transformer (SC-Tr), a superconducting fault current limiter (SC-FCL) and a superconducting power cable (SC-power cable). These components are cooled down at liquid helium (LHe) temperature, 4.2K, in a cryostat with a volume of 854l. The paper indicates a computing procedure of a total heat leak Pleak into the cryostat with a volume of 854l. The paper indicates a computing procedure of a total heat leak Pleak into the cryostat and discusses transmission losses of the superconducting electronic power system, which evaporate the LHe. Pleak, core loss Pcore of the SC-Tr and a.c. loss Pac in the supercondubtor were measured in the PROMISE to be 43W, 180W, and 50W, respectively. The measured Pleak agreed with the theoretical one. In the superconducting power transmission system, the power to operate the refrigerator for liquqefying the evaporated helium must be taken as the transmission loss. If the penalty factor was 500, the transmission loss was estimated to be 137kW and took 13.7% of the transmission capability in the PROMISE.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/6804"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/77.614694","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 1997 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shimizu, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13177","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yokomizu, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13178","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kato, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13179","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tang, Y. J.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13180","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsumura, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13181","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kito, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13182","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satoh, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13183","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satoh, W.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13184","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"ap_su_7_2_1033.pdf","filesize":[{"value":"3.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ap_su_7_2_1033.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/5220/files/ap_su_7_2_1033.pdf"},"version_id":"516116e6-b2c0-4d82-9bdb-691f3ca6e3ad"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Transmission loss of prospective power transmission model system integrated under superconducting environment","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Transmission loss of prospective power transmission model system integrated under superconducting environment","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2006-08-07"},"publish_date":"2006-08-07","publish_status":"0","recid":"5220","relation_version_is_last":true,"title":["Transmission loss of prospective power transmission model system integrated under superconducting environment"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:49:51.920370+00:00"}