{"created":"2021-03-01T06:11:48.779953+00:00","id":5259,"links":{},"metadata":{"_buckets":{"deposit":"5020ac19-a3da-4594-974f-c6b5c6714fd4"},"_deposit":{"id":"5259","owners":[],"pid":{"revision_id":0,"type":"depid","value":"5259"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00005259","sets":["320:321:322"]},"author_link":["13299","13300","13301","13302","13303","13304"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"174","bibliographicPageStart":"166","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Dielectrics and Electrical Insulation [see also IEEE Transactions on Electrical Insulation]","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Partial discharge (PD) inception characteristics of liquid nitrogen (LN_2)/ polypropylene (PP) laminated paper composite insulation system for high temparature superconducting (HTS) cables were investigated in terms of the volume effect and the V-t characteristics. The electrical and optional measurements of PD inception characteristics showed that initial PD could be generated between PP laminated paper layers, as well as in a butt gap. Using a parameter called satistically stressed liquid volume (SSLV) based on the discharge probability in both butt gaps and LN_2 filled thin layers between PP laminated papers, we could systematically analyze and evaluate the volume effect on PD inception stress (PDIE). Furthermore, experimental results revealed that n values of V-t characteristics at PD inception were as high as 80-110. On the other hand, the lower n values obtained at breakdown were interpreted by the intensified PD development in thermal bubbles generated after the PD inception.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/6846"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TDEI.2005.1394027","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2005 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayakawa, N.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13299","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kobayashi, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13300","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hazeyama, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13301","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13302","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yasuda, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13303","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13304","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"01394027.pdf","filesize":[{"value":"3.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"01394027.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/5259/files/01394027.pdf"},"version_id":"499f875c-15f5-4815-9e6e-31561195255c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"High temperature","subitem_subject_scheme":"Other"},{"subitem_subject":"superconducting cable","subitem_subject_scheme":"Other"},{"subitem_subject":"partial discharge","subitem_subject_scheme":"Other"},{"subitem_subject":"butt gap","subitem_subject_scheme":"Other"},{"subitem_subject":"volume effect","subitem_subject_scheme":"Other"},{"subitem_subject":"V-t characteristics","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Partial discharge inception characteristics of LN/sub 2//polypropylene laminated paper composite insulation system for high temperature superconducting cables","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Partial discharge inception characteristics of LN/sub 2//polypropylene laminated paper composite insulation system for high temperature superconducting cables","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2006-08-18"},"publish_date":"2006-08-18","publish_status":"0","recid":"5259","relation_version_is_last":true,"title":["Partial discharge inception characteristics of LN/sub 2//polypropylene laminated paper composite insulation system for high temperature superconducting cables"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:49:54.648531+00:00"}