{"created":"2021-03-01T06:11:50.751132+00:00","id":5290,"links":{},"metadata":{"_buckets":{"deposit":"5f0ebebb-c64d-4274-ad73-71b571a78422"},"_deposit":{"id":"5290","owners":[],"pid":{"revision_id":0,"type":"depid","value":"5290"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00005290"},"item_10_biblio_info_6":{"attribute_name":"\u66f8\u8a8c\u60c5\u5831","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"70","bibliographicPageStart":"64","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Dielectrics and Electrical Insulation [see also IEEE Transactions on Electrical Insulation]"}]}]},"item_10_description_4":{"attribute_name":"\u6284\u9332","attribute_value_mlt":[{"subitem_description":"We measured the electric field in transformer oil/solid composite insulation system under dc voltage application using a Kerr electro-optic measurement system. When a press-board was inserted at the center between two parallel-plane electrodes, the electric field at the mid-point between the pressboard and the cathode decreased with time. On the other hand, the electric field at the mid-point between the pressboard and the anode increased initially with time, reached a maximum value and then fell down. We measured also the electric field before and afterpolarity reversal of the dc voltage. The results revealed that the electric field after polarity reversal reached a magnitude 2.7\u00d7 as much as the average dc applied field. We interpreted the above results on the time transition of the electric field in terms of a charge dynamic model, considering the difference in chargeaccumulation speed on the preddboard between positive and negative charges. This model was verified to be applicable to the time transition of the electric field in oil/solid composite system and BTA added oil/solid composite system as well.","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/6877"}]},"item_10_publisher_32":{"attribute_name":"\u51fa\u7248\u8005","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://dx.doi.org/10.1109/94.590868","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"\u6a29\u5229","attribute_value_mlt":[{"subitem_rights":"Copyright \u00a9 1997 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University\u2019s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org."}]},"item_10_select_15":{"attribute_name":"\u8457\u8005\u7248\u30d5\u30e9\u30b0","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"\u30d5\u30a9\u30fc\u30de\u30c3\u30c8","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_creator":{"attribute_name":"\u8457\u8005","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Okubo, H."}],"nameIdentifiers":[{"nameIdentifier":"13407","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimizu, R."}],"nameIdentifiers":[{"nameIdentifier":"13408","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sawada, A."}],"nameIdentifiers":[{"nameIdentifier":"13409","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kato, K."}],"nameIdentifiers":[{"nameIdentifier":"13410","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, N."}],"nameIdentifiers":[{"nameIdentifier":"13411","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hikita, M."}],"nameIdentifiers":[{"nameIdentifier":"13412","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"\u30d5\u30a1\u30a4\u30eb\u60c5\u5831","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"di_el_ins_4_1_64.pdf","filesize":[{"value":"2.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"di_el_ins_4_1_64.pdf","url":"https://nagoya.repo.nii.ac.jp/record/5290/files/di_el_ins_4_1_64.pdf"},"version_id":"2b272dfa-6a09-412e-ad4a-36df8d1d4c92"}]},"item_language":{"attribute_name":"\u8a00\u8a9e","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"\u8cc7\u6e90\u30bf\u30a4\u30d7","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Kerr electro-optic field measurement and charge dynamics in transformer-oil/solid composite insulation systems","item_titles":{"attribute_name":"\u30bf\u30a4\u30c8\u30eb","attribute_value_mlt":[{"subitem_title":"Kerr electro-optic field measurement and charge dynamics in transformer-oil/solid composite insulation systems"}]},"item_type_id":"10","owner":"1","path":["320/321/322"],"pubdate":{"attribute_name":"\u516c\u958b\u65e5","attribute_value":"2006-08-31"},"publish_date":"2006-08-31","publish_status":"0","recid":"5290","relation_version_is_last":true,"title":["Kerr electro-optic field measurement and charge dynamics in transformer-oil/solid composite insulation systems"],"weko_creator_id":"1","weko_shared_id":3},"updated":"2021-03-01T13:14:31.685192+00:00"}